Data Sheet GE MPR0854FP series front-end Input: 100-120/200-240VAC Output: 54VDC 800W 12VDC 0.8A Features RoHS Compliant Output voltage set to 54Vdc Universal input with PFC No power de-rating at low line input range 2 front panel LEDs: LED1-input LED2 - output, fault, over temp Remote ON/OFF control of the 54V output DC Remote sense on the 54V output DC Meets Power-Over-Ethernet (IEEE802.3af) No minimum load requirements Applications Droop load sharing Hot Plug-able 48V distributed power architectures DC Efficiency: typically 92.5% 50% load Datacom and Telecom applications and 90.0% 20% load Mid to high-end Servers 12V for backup power DC Auto recoverable OC & OT protection Enterprise Networking Radiated emissions hardened enclosure Network Attached Storage Operating temperature: -10 - 70 C (de-rated above 50C) Telecom Access Nodes Digital status & control: PMBus compliant serial bus Routers/Switches nd EN/IEC/UL60950-1 2 edition UL, CSA and VDE ATE Equipment EMI: class A FCC docket 20780 part 15, EN55022 Meets EN6100 immunity and transient standards Shock & vibration: IEC-68-2 Description The MPR0854FP series of front ends provide efficient isolated power from world-wide commercial AC mains. Offered in the industry standard compact 1U form factor, these front ends provide comprehensive solutions for systems connected to commercial ac mains. This high-density front end can be ordered either as a front-to-back or back-to-front airflow product. It is designed for 2 minimal space utilization and is highly expandable for future growth. The industry standard PMBus compliant I C communications buss offers a full range of control and monitoring capabilities. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. Intended for integration into end-user equipment. All the required procedures for CE marking of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards. + PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) October 19, 2017 2015 General Electric Company. All rights reserved. Page 1 Data Sheet GE MPR0854FP series rectifier Input: 100-120/200-240V Output: 54V 800W 12V 0.8A AC DC DC Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the Technical Requirement. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous VIN 0 264 VAC 1 Operating Ambient Temperature TA -10 70 C Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 1500 VAC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Symbol Min Typ Max Unit Operational Range V 90 110/230 264 V IN ac FIN Frequency Range 47 50/60 63 Hz VIN Main Output Turn OFF 68 75 VAC VIN Main Output Turn ON 76 84 VAC Maximum Input Current VIN= 100VAC 9.2 IIN AAC 4.6 (V = 54V I =14.8A) V = 200V OUT DC, OUT IN AC Cold Start Inrush Current (Excluding x-caps, 25 C) 30 A PEAK I IN cycle duration Efficiency (TAMB=25 C, VOU T = 54VDC, IO = 14.8A) input 100 - 240 VIN 100% load 88 75% load 87 % 50% load 84 20% load 77 Power Factor (Vin=90 - 264V , I = 14.8A) PF 0.8 0.99 AC OUT Holdup time (VIN = 90VAC, TAMB 25 C, VOUT = 54VDC, IOUT = 14.8A) T 10 ms 2 Power Fail Warning (AC OK L) Assertion delay 10 ms T 3 Start of assertion 5 ms Level of voltage decay VDC 43 VDC Leakage Current (VIN= 264VAC, FIN = 60Hz) IIN 3.5 mA Isolation Input/Output 3000 V AC V AC Input/Frame 1500 VAC Main output or main rtn/Frame 2121 VDC VDC 3.3V or 12V /main output 2121 V STNDBY DC 1 Derated above 50 C at 2.5%/C 2 PFW does not trigger for power interruptions lasting less than 10ms ( cycle) 3 The signal shall assert at least 5ms prior to decaying of the output voltage below 43V DC October 19, 2017 2015 General Electric Company. All rights reserved. Page 2