Data Sheet GE TM 12A Digital PicoDLynx : Non-Isolated DC-DC Power Modules 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Features Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863. Compliant to REACH Directive (EC) No 1907/2006. Compatible in a Pb-free or SnPb reflow environment Compliant to IPC-9592 (September 2008), Category 2, Class II DOSA based Wide Input voltage range (3Vdc-14.4Vdc) Output voltage programmable from 0.6Vdc to 5.5Vdc via external resistor. Digitally adjustable down to RoHS Compliant 0.45Vdc TM Digital interface through the PMBus protocol TM Tunable Loop to optimize dynamic output voltage Applications response Distributed power architectures Flexible output voltage sequencing EZ-SEQUENCE Intermediate bus voltage applications Power Good signal Telecommunications equipment Fixed switching frequency with capability of external synchronization Servers and storage applications Output overcurrent protection (non-latching) Networking equipment Overtemperature protection Industrial equipment Remote On/Off Vin+ Vout+ VIN VOUT Ability to sink and source current VS+ PGOOD Cost efficient open frame design RTUNE MODULE Small size: 12.2 mm x 12.2 mm x 8.5 mm SEQ CTUNE (0.48 in x 0.48 in x 0.335 in) CLK Cin TRIM Co DATA Wide operating temperature range -40C to ADDR0 SMBALRT RTrim ADDR1 105C(Ruggedized: -D), 85C(Regular) ON/OFF RADDR1 RADDR0 ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 SIG GND Recognized, DIN VDE 0868-1/A11:2017 (EN62368- SYNC GND VS- 1:2014/A11:2017) GND ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM The 12A Digital PicoDLynx power modules are non-isolated dc-dc converters that can deliver up to 12A of output current. These modules operate over a wide range of input voltage (V = 3Vdc-14.4Vdc) and provide a precisely regulated output voltage from IN 0.45Vdc to 5.5Vdc, programmable via an external resistor and PMBus control. Features include a digital interface using the PMBus protocol, remote On/Off, adjustable output voltage, over current and over temperature protection. The PMBus interface supports a TM range of commands to both control and monitor the module. The module also includes the Tunable Loop feature that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) 2016 General Electric Company. July 10, 2020 All rights reserved. GE Data Sheet TM 12A Digital PicoDLynx : Non-Isolated DC-DC Power Modules 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 15 V IN Continuous SEQ, SYNC, VS+ All 7 V CLK, DATA, SMBALERT All 3.6 V Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 3 14.4 Vdc IN Maximum Input Current All I 9 Adc IN,max (VIN=3V to 14V, IO=IO, max ) V = 0.6 Vdc I 52 mA O,set IN,No load Input No Load Current (VIN = 12Vdc, IO = 0, module enabled) V = 5Vdc I 85 mA O,set IN,No load Input Stand-by Current All IIN,stand-by 6.5 mA (VIN = 12Vdc, module disabled) 2 2 Inrush Transient All I t 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance VIN =0 to All 400 mAp-p 14V, IO= IOmax See Test Configurations) Input Ripple Rejection (120Hz) All -55 dB 2016 General Electric Company. July 10, 2020 Page 2 All rights reserved.