Data Sheet GE TM 12A Digital Pico SlimLynx Open Frame: Non-Isolated DC-DC Modules 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Features Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863. Compliant to REACH Directive (EC) No 1907/2006 Compliant to IPC-9592 (September 2008), Category 2, Class II Ultra low height design for very dense power applications. Small size: 12.2 mm x 12.2 mm x 2.9 mm (Max) (0.48 in x 0.48 in x 0.116 in) Output voltage programmable from 0.6Vdc to 5.5Vdc RoHS Compliant via external resistor. Digitally adjustable down to 0.45Vdc Wide Input voltage range (3Vdc-14.4Vdc) Applications Wide operating temperature range -40C to 85C . See derating curves Distributed power architectures DOSA approved footprint Intermediate bus voltage applications TM Digital interface through the PMBus protocol Telecommunications equipment TM Tunable Loop to optimize dynamic output voltage Servers and storage applications response Networking equipment Flexible output voltage sequencing EZ-SEQUENCE Power Good signal Industrial equipment Remote On/Off Vin+ Vout+ VIN VOUT Fixed switching frequency with capability of external VS+ PGOOD synchronization RTUNE MODULE Output overcurrent protection (non-latching) SEQ CTUNE CLK Overtemperature protection Cin TRIM Co DATA Ability to sink and source current ADDR0 SMBALRT RTrim ADDR1 Compatible in a Pb-free or SnPb reflow environment ON/OFF RADDR1 RADDR0 ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 SIG GND Recognized, DIN VDE 0868-1/A11:2017 (EN62368- SYNC GND VS- GND 1:2014/A11:2017) ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM The 12A Digital Pico SlimLynx Open Frame power modules are non-isolated dc-dc converters that can deliver up to 12A of output current. These modules operate over a wide range of input voltage (VIN = 3Vdc-14.4Vdc) and provide a precisely regulated output voltage from 0.45Vdc to 5.5Vdc, programmable via an external resistor and PMBus control. Features include a digital interface using the PMBus protocol, remote On/Off, adjustable output voltage, over current and over temperature protection. The PMBus TM interface supports a range of commands to both control and monitor the module. The module also includes the Tunable Loop feature that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) August 17, 2020 2016 General Electric Company. All rights reserved. GE Data Sheet TM 12A Digital Pico SlimLynx Open Frame: Non-Isolated DC-DC Power 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Modules Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 15 V IN Continuous SEQ, SYNC, VS+ All 7 V CLK, DATA, SMBALERT All 3.6 V Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 3 14.4 Vdc IN Maximum Input Current All I 11 Adc IN,max (VIN=3V to 14.4V, IO=IO, max ) V = 0.6 Vdc I 50 mA O,set IN,No load Input No Load Current (VIN = 12Vdc, IO = 0, module enabled) VO,set = 5.5Vdc IIN,No load 180 mA Input Stand-by Current All I 8 mA IN,stand-by (VIN = 12Vdc, module disabled) 2 2 Inrush Transient All I t 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance VIN =0 to 14V, IO= All 30 mAp-p I See Test Configurations) Omax Input Ripple Rejection (120Hz) All -55 - dB August 17, 2020 2016 General Electric Company. All rights reserved. Page 2