Product Specification sheet 10G Series Plug-in Switch Mode Power Supply Unit INPUT MODEL 5V DC 6V DC 7.5V DC 9V DC 12V DC AC Input Voltage Min 90V 90V 90V 90V 90V Normal 100 100 100 100 100 240V 240V 240V 240V 240V Max 264V 264V 264V 264V 264V AC Input Frequency Min 47Hz 47Hz 47Hz 47Hz 47Hz Normal 50 60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz Max 63 Hz 63 Hz 63 Hz 63 Hz 63 Hz AC Input Current 230V AC (max) 0.3A 0.3A 0.3A 0.3A 0.3A Input Power (max) 17.14W 17.14W 14.10W 17.14W 17.14W AC Inrush Current* No damage shall be incurred and input fuse shall not blow Primary current protection An internal fuse on the AC input line is provided. Configuration Wall-mount, AU pin, 2 conductors <Active, Neutral> * 230V AC 50Hz. Full-load. 25C, Cold start. Power consumption at no load MODEL 5V DC 6V DC 7.5V DC 9V DC 12V DC Input current 25mA 25mA 25mA 25mA 25mA Input 230V AC 50 Hz 0.6W max 0.6W max 0.5W max 0.6W max 0.6W max OUTPUT MODEL 5V DC 6V DC 7.5V DC 9V DC 12V DC Normal DC Output Voltage +5V +6V +7.5V +9V +12.0V Maximum Load Current 2.0A 1.67A 1.33A 1.1A 1.0A Minimum Load Current 0.05A 0.05A 0.0A 0.05A 0.05A Rated Output Power 10.0W 10.0W 14.10W 10.0W 12.0W Efficiency * 70.0% 70.0% 70.7% 70.0% 70.0% Load Regulation 5% from 10% to 100% of rated load Ripple and Noise ** 100mV Over-current Protection Adaptor protected with 200% of rated output. Over-voltage Protection Zener clamp. Short-circuit Protection The adaptor shall not be damaged by shorting the DC output to Ground with auto recovery functioning correctly. Hold-up Time (min) *** 10mS Output over-shoot <7% of nominal voltage value Temperature coefficient Output voltage temperature coefficient 0.05%/C Turn-on Delay (max) 2 Seconds Rise Time Start-up rise time of <20mS to rise to within regulation limits * Minimum at normal input voltage and full load. ** Voltage measured P-P at 20MHz and output parallel with 100nF ceramic & 10uF electrolytic capacitors to ground. Temperature at 25C and nominal AC input voltage. *** At nominal AC voltage and full load. Page 1 of 5 www.accesscomms.com.au/specs/adaptor 10Gspec.pdf Copyright 2009 Access Communications Pty Ltd Product Specification sheet 10G Series Plug-in Switch Mode Power Supply Unit MECHANICAL MODEL 5V DC 6V DC 7.5V DC 9V DC 12V DC Weight (Max) 108g 108g 100g 108g 108g Dimensions 72.0(L) x 38.0(W) x 26.5(D)mm. Input Plug Type Wall type, SAA 2-pin AS/NZS3112:2000 Output Cord Wire: 18AWG/2C, 2000mm. Output Plug DC Barrel Plug (with fork & groove) ENVIRONMENTAL Cooling Natural convection. Operating Te mperature 0C to +40C Storage Temperature -20C to +80C Operating Humidity 10 ~ 90 % Non-condensing Storage Humidity 10 ~ 90 % Non-condensing SAFETY Dielectric withstanding 3000V AC 10mA for 1 minute.. voltage test (Hi-pot test) input to output Insulation Resistance 10M at 500V DC between Primary Active, Neutral line and secondary. Leakage Current 0.25mA maximum at normal AC input voltage and frequency RELIABILITY Mean Time Between The power supply is designed to have a MTBF of 50,000 Failure (MTBF) hours. COMPLIANCE Electrical Safety Certificate NSW20945 EMC Energy Efficiency 5.0V 6.0V 7.5V 9V 12V (MEPS Mark) IV Page 2 of 5 www.accesscomms.com.au/specs/adaptor 10Gspec.pdf Copyright 2009 Access Communications Pty Ltd