Product Specification sheet 60D Series In-line Switch Mode Power Supply Unit INPUT MINIMUM NORMAL MAXIMUM AC Input Voltage 90V AC 100 240V AC 264V AC AC Input Frequency 47 Hz 50 / 60 Hz 63 Hz AC Input Current 115V AC (max) 1.5A AC Input Current 230V AC (max) 0.8A AC Inrush Current* 115V AC, 60Hz No damage shall occur and the input fuse shall not blow. AC Inrush Current* 230V AC, 50Hz Primary current protection An internal fuse on the AC input line is provided. Configuration 3-conductors, <Active, Neutral, Earth> * At full-load, 25C, cold start. Power consumption at no load (maximum) Input 240V AC 50 Hz 0.75W max OUTPUT T1250 Series T1540 Series T2425 Series Normal DC Output Voltage +12.0V +15.0V +24.0V Minimum Load Current 0.0A 0.0A 0.0A Maximum Load Current 5.0A 4.0A 2.5A Maximum Output Power 60W 60W 60W Ripple and Noise * 200mV 200mV 200mV Efficiency (min) ** 80% 80% 80% Over-voltage protection (max) 25.2V DC Over-current protection (max) 8A with auto-recovery Total Output Regulation +/- 5% Dynamic Load Regulation *** +/- 5% Short-circuit protection No damage when shorting the DC output to ground. Open-circuit protection When primary power is applied with no load on any output level, no damage or hazardous conditions should occur. Drop-out With half cycle input voltage drop-out, the unit shall meet the regulation requirement and operate within the prescribed voltages with a drop-out pulse repetition rate of 500mS under full load and with normal AC input voltage. * Voltage measured P-P at 20MHz and output parallel with 0.1uF & 47uF capacitor to ground. Temperature at 25C and normal AC input voltage. ** At normal input voltage and full load. *** For 50%~100%~50% load change at any frequency up to 250Hz with 50% duty. MECHANICAL Dimensions 115(L) x 63(W) x 35.5(H)mm maximum. Weight 350g maximum. Input Plug Type 3-pin 3-conductors, <Active, Neutral, Earth> Output Cord Wire: SPT-1, VW-1, 18AWG, 1828mm. Output Plug 11(L) x 5.5(D) x 2.5(ID)mm Page 1 of 4 www.accesscomms.com.au/specs/adaptor 60Dspec.pdf Copyright 2004 Access Communications Pty Ltd Product Specification sheet 60D Series In-line Switch Mode Power Supply Unit ENVIRONMENTAL Cooling Natural convection. Operating Te mperature 0C to +40C Storage Temperature -40C to +60C Operating Humidity 20 ~ 85 % RH. Non-condensing Storage Humidity 5 ~ 95 % RH. Non-condensing SAFETY Dielectric withstanding 1,500V AC, 10mA, 1 minute (Primary to Secondary) voltage test (Hi-pot test) 1,500V AC, 10mA, 1 minute (Primary to FG *) Insulation Resistance > 100M at 500V DC between Primary Active, Neutral line and secondary. Leakage Current 0.5mA maximum at normal AC input voltage and frequency * Applies to 12V model only. Australian Certificate of Approval (Electrical Safety) Q04547 RELIABILITY Mean Time Between The power supply is designed to have a MTBF of 40,000 / 50,000 (*) Failure (MTBF) operating hours at nominal AC input voltage, 80% full load and 25C ambient temperature. Burn-in Test 4 hours at 40C +/- 5C, normal input voltage, 80% of maximum load. (*) 40,00 hours for 24V model and 50,00 hours for the 12V model RATING PLATE Page 2 of 4 www.accesscomms.com.au/specs/adaptor 60Dspec.pdf Copyright 2004 Access Communications Pty Ltd