EKI-1242EIMS
Modbus RTU/TCP to EtherNet/IP Fieldbus
EKI-1242IEIMS
Gateway
Features
Supports dual power input for power redundancy
Seamless integrate Modbus RTU/TCP and EtherNET/IP communication
Modbus Master mode supports 64 connections
Mounts on DIN-rail and Wall mount
Designed for protocol extensibility and adaption
Built-in real time diagnostic to increase highly efficiency of device
management
'I' models support a wide operating temperature
Introduction
The EKI-1242EIMS Industrial Fieldbus gateway providing seamless communication between Fieldbus and Industrial Ethernet and supports different protocol devices and integrates
new and existing Modbus RTU/TCP devices to the EtherNet/IP network. To collect data and exchange data between Modbus RTU/TCP to EtherNet/IP. EKI-1242EIMS is a simple and
cost-effective way to bring the advantages of fast data transmissions between different devices.
Specifications
Ethernet Communication
General
Protocols EtherNet/IP, Modbus TCP LED Indicators System: Power, Syste, Protocol Status
LAN: Speed, Link/Active, Error
Number of Ports 4
Reboot Trigger Built-in WDT (watchdog timer)
Speed 10/100 Mbps, Auto MDI/MDIX
MicroSD Card Configuration backup and restore
Connector 8-pin RJ45
Protection Built-in 1.5 KV magnetic isolation
Mechanics
Dimensions (W x H x D) 42 x 140 x 95 mm (1.66" x 5.52" x 3.75")
Serial Communications
Enclosure Metal with solid mounting hardware
Port Type RS-232/422/485, software selectable
Mounting DIN-rail, Wall
No. of Ports 2
Weight 0.592 Kg
Protocol Modbus RTU
Port Connector DB9 male Power Requirements
Data Bits 5, 6, 7, 8
Power Input 12 ~ 48 V , redundant dual inputs
DC
Stop Bits 1, 1.5, 2
Power Connector Terminal block
Parity None, Odd, Even, Space, Mark Power Consumption 5.2 W
Flow Control XON/XOFF, RTS/CTS
Environment
Baud Rate 50 bps ~ 921.6 kbps
Operating Temperature -10 ~ 60 C (14 ~ 140 F)
Serial Signals RS-232: TxD, RxD, CTS, RTS, DCD, RI, GND
' I' models: -40 ~ 75 C (-40 ~ 167 F)
RS-422: TxD+, TxD-, RxD+, RxD-, GND
Storage Temperature -40 ~ 85 C (-40 ~ 185 F)
RS-485: Data+, Data-, GND
Operating Humidity 10 ~ 95% RH
Software
Regulatory Approvals
Modbus RTU/TCP
EMC CE, FCC Part 15 Subpart B (Class A)
Mode Master
Functions Support 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. Number of Connections 64 connections
EtherNet/IP
Class Adapter
Max. Number of Connections 32 explicit messaging, 5 implicit messaging
Max. Total I/O Data Size Input: 496 bytes
Output: 496 bytes
Industrial Ethernet Soultions
All product specifications are subject to change without notice. Last updated: 18-Jan-2018EKI-1242EIMS
EKI-1242IEIMS
Dimensions Unit: mm [inch]
33 35
[1.299] [1.378]
15
[0.591]
104 [4.094]
95 [3.740]
42 [1.654]
30.50 [1.201] 40 [1.575] 42 [1.654]
95 [3.740]
Ordering Information
EKI-1242EIMS Modbus RTU/TCP to EtherNet/IP Fieldbus Gateway
EKI-1242IEIMS Modbus RTU/TCP to EtherNet/IP Protocol Gateway
with wide operating temperature
Online Download www.advantech.com/products
140 [5.512] 9.80 [0.386]
20.53
[0.808]
11.60
[0.457]
47.95 47.05
[1.888] [1.852]
140 [5.512]