Special DATA LDAOGGERSTA LOGGERS product features Simple LoggerSimple Logger II TRMS V II TRMS Clamp-On Currentoltage 600Vca /dc Model L261 & 850Vdc Model L481 One channel loggers for voltage measuring, monitoring and troubleshooting SPECIFICATIONS IP 40 Rated MODELS L261 L481 ELECTRICAL Channels One FEATURES Input Connection Two recessed 4mm safety banana jacks TRMS voltage recording up to 600Vca /dc Measurement Range 0 to 600Vac /dc -850 to 850Vdc (Model L261) Resolution 0.1V Bipolar voltage recording up to 850Vdc Accuracy (50/60Hz) 0 to 5V: unspecified 0 to 5V: unspecified 5 to 50V: 5 to 50V: (Model L481) (0.5% of Reading + 1V) (0.5% of Reading + 1V) AC: 64 samples per cycle and 50 to 600V: 50 to 850V: DC: 8 samples per sec (Model L261) (0.5% of Reading + 0.5V) (0.5% of Reading + 0.5V) Programmable storage rates from Input Impedance 40M 8 every second to 1 every day Sample Rate 64 samples/cycle Maximum of 8 per second 4 user selectable storage modes Storage Rate Programmable from 8 every second to 1 every day Stores up to 240,000 measurements in Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM ) and Alarm non-volatile memory Recording Length 15 minutes to 8 weeks, programmable using DataView Powered by standard Alkaline batteries Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory and Lightweight, compact, fits anywhere will be retained even if the battery is low or removed. 5 LED indicators quickly and clearly Communication USB 2.0 optically isolated display logger status Power Source 2 x 1.5V AA-cell Alkaline batteries (included) Includes FREE DataView software Battery Life 100 hours to >45 days for data storage, real-time display, (dependent on sample rate and recording length) analysis and report generation MECHANICAL Optically isolated USB 2.0 Dimensions 4.94 x 2.75 x 1.28 (125 x 70 x 32mm) communication cable included Weight (with battery) 6.4 oz (181g) EN 61010-1 300V CAT IV 600V CAT III Case UL94-V0 Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz) APPLICATIONS ( MODEL L261) Shock IEC 68-2-27 (30G) Surge and Sag recording Drop IEC 68-2-32 (1m) Long term supply monitoring Industrial, commercial and residential monitoring Monitor voltage harmonics Find intermittent voltage problems PRODUCT INCLUDES Machine monitoring APPLICATIONS ( MODEL L481) Set of two color-coded 5 ft voltage leads, color-coded alligator clips (red/black), Rail voltage monitoring USB type A to 5 pin Mini-B, and USB Long term supply monitoring stick supplied with DataView software and user manual. Find intermittent voltage problems Machine monitoring Windmill monitoring CATALOG NO. DESCRIPTION 2126.05 Simple Logger II Model L261 (1-Channel, TRMS, 600Vca /dc , DataView software) 2126.25 Simple Logger II Model L481 (1-Channel, 850Vdc , DataView software) www.aemc.com Technical Assistance (800) 343-1391 DATAVIEW Software for Data Loggers Data Analysis and Reporting Software for Data Loggers Typical DataView Functional Displays Configure all data logger functions of the Simple Logger II Models Displa y and analyze real-time data on your PC Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more Create and store a complete libr ary of configur ations that can be uploaded to the logger as needed Zoom in and out and pan through sections of the graph to analyze the data Download, display and analyze recorded data Display waveforms, trend graphs, harmonics (AC models) and text summaries Quick and simple configuration of all functions and Create custom views and reports settings from one dialog box. Print reports using standard or custom templates you design Free software upgrades are available on our website www.aemc.com Configure all alarm functions with straightforward selections. Real-time display of all active inputs on computer through DataView software. Real-time view of trend, waveform and status screens. www.aemc.com Technical Assistance (800) 343-1391