Series AM10CW-NZ 10 Watt DC-DC Converter Picture coming soon FEATURES: Wide 4:1 Input Voltage Range Operating Temperature -40C to +85C High efficiency up to 88% Output Over Voltage protection 1500 VDC Isolation Continuous Short Circuit Protection Over Current Protection Input Under voltage Protection No load consumption 0.12W Remote On/Off control Models Single output Output Output Max Input Isolation Efficiency Model Voltage Current max Capacitive Voltage (V) (VDC) (%) (V) (A) Load (uF) AM10CW-2403S-NZ 9-36 3.3 2.4 1500 2200 79 AM10CW-2405S-NZ 9-36 5 2 1500 2200 83 AM10CW-2409S-NZ 9-36 9 1.11 1500 680 86 AM10CW-2412S-NZ 9-36 12 0.83 1500 470 87 AM10CW-2415S-NZ 9-36 15 0.66 1500 330 87 AM10CW-2424S-NZ 9-36 24 0.41 1500 100 88 AM10CW-4803S-NZ 18-75 3.3 2.4 1500 2200 79 AM10CW-4805S-NZ 18-75 5 2 1500 2200 83 AM10CW-4812S-NZ 18-75 12 0.83 1500 470 87 AM10CW-4815S-NZ 18-75 15 0.66 1500 330 87 AM10CW-4824S-NZ 18-75 24 0.41 1500 100 88 Models Dual output Output Output Max Input Isolation Efficiency Model Voltage Current max Capacitive Voltage (V) (VDC) (%) (V) (A) Load (uF) AM10CW-2405D-NZ 9-36 5 1 1500 1000 83 AM10CW-2412D-NZ 9-36 12 0.41 1500 470 87 AM10CW-2415D-NZ 9-36 15 0.33 1500 330 87 AM10CW-2424D-NZ 9-36 24 0.2 1500 100 87 AM10CW-4805D-NZ 18-75 5 1 1500 1000 83 AM10CW-4812D-NZ 18-75 12 0.41 1500 470 87 AM10CW-4815D-NZ 18-75 15 0.33 1500 330 87 AM10CW-4824D-NZ 18-75 24 0.2 1500 100 87 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units 24 Vin 9-36 Voltage range VDC 48 Vin 18-75 Filter Pi 24 Vin -0.7 - 50 Absolute Maximum Rating (100ms) VDC 48 Vin -0.7 - 100 24 Vin 12 No Load Input Current mA 48 Vin 8 24 Vin 40 Input reflected current mA 48 Vin 30 24 Vin 6.5 Input Under voltage turn off VDC 48 Vin 15.5 Startup time Nominal input, resistive load 10 ms On 3.5-12VDC or leave open Remote On/Off Control Off 0-1.2VDC or connect to GND, idle current 6-10mA www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 1 of 3 North America only Series AM10CW-NZ 10 Watt DC-DC Converter Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 60 sec, <1mA 1500 VDC Resistance 500VDC >1000 MOhm Capacitance I/O, 100KHz/0.1V 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 5% to 100% load 2 3 % Voltage balance (Dual Output Models) Balanced Load 1.5 % Over voltage protection 110-160 % of Vout Over current protection 110-190 % of Iout Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation (Single) Full load, LL to HL 0.5 % of Vin Line voltage regulation (Dual) Full load, LL to HL 1 % of Vin Load voltage regulation (Single) 5% to 100% load 1 % Load voltage regulation (Dual) 5% to 100% load 1.5 % 50% load on one output & 10-100% Cross Regulation (Dual Output Models) 5 % load on second load o Temperature coefficient 100% load 0.03 %/ C Ripple & Noise 20MHz Bandwidth, 5-100% load 80 mV p-p Transient recovery time 25% load step change 500 s Transient recovery deviation 25% load step change 5 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 350 KHz o Operating temperature See derating curve -40 to +85 C o Storage temperature -55 to +125 C o Maximum case temperature 100 C Cooling Free air convection Humidity 95 % RH Case material Aluminum Alloy Weight 15 g Dimensions (L x W x H) 1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm o MTBF >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) o Maximum soldering temperature 1.5mm from case for 10 sec 300 C Environmental Specifications Parameters Test mode 10-55Hz Vibration Acceleration 10G, 30min one cycle, every axis tested Safety Specifications Parameters Approval CE, UL, pending EN 55022, class B (with the recommended EMC circuit) Electrostatic Discharge Immunity IEC 61000-4-2, Contact 4KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient / Burst Immunity IEC 61000-4-4, 2KV, Criteria B (with the recommended EMC circuit) Standards Surge Immunity IEC 61000-4-5, 2KV, Criteria B (with the recommended EMC circuit) RF, Conducted Disturbance Immunity IEC 61000-4-6, 3 Vrms, Criteria A Voltage dips, Short Interruptions & Voltage IEC 61000-4-29: 0-70%, Criteria B variations Immunity www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 2 of 3 North America only