Series AM6CW-NZ 6 Watt DC-DC Converter FEATURES: Wide 4:1 Input Voltage Range Operating Temperature -40C to +85C High efficiency up to 88% Output Over Voltage protection 1500 & 2250VDC Isolation Continuous Short Circuit Protection Over Current Protection Input Under Voltage Protection No load consumption 0.12W Models Single output Max Output Output Input Voltage Isolation Capacitive Efficiency Model Voltage Current max (V) (VDC) Load (%) (V) (mA) (uF) AM6CW-2403S-NZ 9-36 3.3 1500 1500 1800 79 AM6CW-2405S-NZ 9-36 5 1200 1500 1000 83 AM6CW-2409S-NZ 9-36 9 667 1500 680 85 AM6CW-2412S-NZ 9-36 12 500 1500 470 87 AM6CW-2415S-NZ 9-36 15 400 1500 220 88 AM6CW-2424S-NZ 9-36 24 250 1500 100 88 AM6CW-4803S-NZ 18-75 3.3 1500 1500 1800 79 AM6CW-4805S-NZ 18-75 5 1200 1500 1000 83 AM6CW-4812S-NZ 18-75 12 500 1500 470 87 AM6CW-4815S-NZ 18-75 15 400 1500 220 88 AM6CW-4824S-NZ 18-75 24 250 1500 100 88 AM6CW-11005S-NZ 40-160 5 1200 1500 1000 81 AM6CW-11012S-NZ 40-160 12 500 1500 100 83 AM6CW-11015S-NZ 40-160 15 400 1500 100 85 AM6CW-11024S-NZ 40-160 24 250 1500 47 85 AM6CW-11005SH22-NZ 40-160 5 1200 2250 1000 80 AM6CW-11012SH22-NZ 40-160 12 500 2250 470 84 AM6CW-11015SH22-NZ 40-160 15 400 2250 220 85 AM6CW-11024SH22-NZ 40-160 24 250 2250 100 86 Models Dual output Output Output Max Input Isolation Efficiency Model Voltage Current max Capacitive Voltage (V) (VDC) (%) (V) (mA) Load(uF) AM6CW-2405D-NZ 9-36 5 600 1500 470 83 AM6CW-2412D-NZ 9-36 12 250 1500 100 87 AM6CW-2415D-NZ 9-36 15 200 1500 100 88 AM6CW-2424D-NZ 9-36 24 125 1500 100 88 AM6CW-4805D-NZ 18-75 5 600 1500 470 83 AM6CW-4812D-NZ 18-75 12 250 1500 100 87 AM6CW-4815D-NZ 18-75 15 200 1500 100 88 Note: Note: *Add suffix -K for optional heatsink **Add suffix -ST for optional screw terminal bottom plate ***Add suffix -STD for optional DIN Rail screw terminal bottom plate ****Add suffix -K-ST for optional heat sink with screw terminal bottom plate *****Add suffix -K-STD for optional heat sink with DIN Rail screw terminal bottom plate NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13.F 1 of 7 North America only Series AM6CW-NZ 6 Watt DC-DC Converter Input Specifications Parameters Nominal Typical Maximum Units 24 9-36 Voltage range 48 18-75 VDC 110 40-160 Filter Pi 24 -0.7 - 50 Absolute Maximum Rating (1s) 48 -0.7 - 100 VDC 110 -0.7 - 180 24 12 No Load Input Current mA 48, 110 8 Input reflected current 25 mA 24 6.5 Input Under voltage turn off* 48 15.5 VDC 110, 2250V Isolation 33 Startup time For 110Vin, 2250V Isolation models 10 ms *Except for 110V input 1500V isolation models only. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec, <1mA 1500 & 2250 VDC Tested Input or Output / Case voltage 60 sec, <1mA, 110Vin, 2250V Isolation models 1600 Resistance 500VDC >1000 MOhm Capacitance I/O, 100KHz/0.1V 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Voltage balance (Dual Output Models) Balanced Load 1.5 % Over voltage protection 110-160 % of Vout 24 & 48V input models only 110-190 Over current protection % of Iout 110Vin, 2250V Isolation models 120-210 Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation (Single) Full load, LL to HL 0.5 % of Vin Line voltage regulation (Dual) Full load, LL to HL 1 % of Vin 0-100% load, 110Vin, 2250V Isolation models 1 Load voltage regulation (Single) % 5- 100% load, others 1 Load voltage regulation (Dual) 5% to 100% load 1.5 % Cross Regulation (Dual Output Models) 25% load on 1st output - 100% load on 2nd load 5 % o Temperature coefficient 100% load 0.03 %/ C Ripple & Noise 100 mV p-p 25% load step change, 110Vin, 2250V Isolation 0.5 Transient recovery time mS 25% load step change, others 1 Transient recovery deviation 25% load step change 8 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz o Operating temperature Derating above 71C -40 to +85 C o Storage temperature -55 to +125 C o Maximum case temperature 100 C Cooling Free air convection Humidity 95 % RH Case material Aluminum Alloy Pin mountable 15 Weight With optional -ST mounting plate: 35 g With optional -STD mounting plate: 55 With optional -K Pin mountable 20 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13.F 2 of 7 North America only