Click on Series name for product info on aimtec.com Series AME15-MAZ 15 Watt AC-DC / DC-DC Converter FEATURES: 4000VAC I/O Isolation RoHS compliant Operating temperature: -40 to +85C Soft start Over load, Over Voltage, Short Circuit Protection Energy Star compliant Universal input: 90-264VAC, 47-440Hz CE, cULus, CB approvals Models CB Single output Efficiency (%) Input Voltage Input voltage Output Output Current Maximum Model (VAC/Hz) (VDC) Voltage (V) max (A) capacitive Load (F) 115 230 VAC VAC AME15-3.3SMAZ 90-264/47-440 130-370 3.3 3 4700 73 73 AME15-5SMAZ 90-264/47-440 130-370 5 3 2200 76 78 AME15-12SMAZ 90-264/47-440 130-370 12 1.25 1000 78 79 AME15-15SMAZ 90-264/47-440 130-370 15 1 680 79 82 AME15-24SMAZ 90-264/47-440 130-370 24 0.63 470 82 84 Models Dual output Efficiency Input Voltage Input voltage Output Output Current Maximum (%) Model (VAC/Hz) (VDC) Voltage (V) max (A) Capacitive Load (F) 115 230 VAC VAC AME15-5DMAZ 90-264/47-440 130-370 5 1.5 1000 78 79 AME15-12DMAZ 90-264/47-440 130-370 12 0.63 470 81 82 AME15-15DMAZ 90-264/47-440 130-370 15 0.5 330 82 83 Input Specifications Parameters Conditions Typical Maximum Units 115 VAC 350 mA Current 230 VAC 180 mA 115 VAC 20 A Inrush current <2ms (Cold Start) 230 VAC 30 A 115 VAC 0.1 mA Leakage current 264 VAC 0.2 mA External Fuse (recommend) slow blow type 2 A Input Dissipation 110/230Vac 0.2 W Under Voltage Protection 85 VAC Start-up time 350 ms Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Line regulation LL-HL 1 % Load regulation (single) 0-100% 1 % st nd Cross regulation (dual) 25% load - 1 out, 100% load 2 out 5 % Transient Recovery Time 300 s Transient Response Deviation 25% load step 2 % of Vout 75 3.3 / 5V Models Ripple & Noise* 12 / 15V Models 100 mVp-p 24V 150 Hold-up time min 20 ms * RippleandNoisearemeasuredat20MHzbandwidthbyusinga0.1F(M/C)and47F(E/C)parallelcapacitor www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.O 1 of 4 North America only Series AME15-MAZ 15 Watt AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 VAC M Isolation resistance >1000 General Specifications Parameters Conditions Typical Maximum Units Switching frequency 132 KHz Protection class Class II Over load protection Fold Back 130 % Over voltage protection Zener diode clamp Short Circuit protection Continuous Short Circuit restart Auto recovery o o Operating temperature With derating over 55 C -40 to +85 C o Storage temperature -40 to +100 C o Max Case temperature 100 C o Temperature coefficient 0.02 % / C Cooling Free air convection Humidity 95 % RH Weight 100 g Dimensions (L x W x H) 2.56 x 1.83 x 0.79 inches 65.0 x 46. 5 x 20.1 mm , 0.5mm o > 400,000hrs (MIL-HDBK -217F, t=+25 C) MTBF > 100,000hrs (MIL-HDBK -217F, t=at highest operating temperature) Case material Plastic (flammability to UL 94V-0) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals cULus, CE, CB IEC EN UL 60601-1, 2 x MOOP,CSA-C22.2 No. Medical Electrical Equipment 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Standards Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.O 2 of 4 North America only