Click on Series name for product info on aimtec.com Series AME3-AZ 3Watt AC-DC Converter FEATURES: I/O Isolation 3000VAC RoHS compliant o o Operating Temp: -40 Cto +80 C Energy Star compliant Over load, Short Circuit Protection Ultra small package Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC Models Single output Maximum Efficiency Input Input Temperature Output Output capacitive Full load (%) Model Voltage Voltage range Voltage Current max Load 115 230 277 480 (VAC/Hz) (VDC) (C) (V) (mA) VAC VAC VAC VAC (F) AME3-3.3SAZ 90-305/47-440 130-430 -40 to +80 3.3 900 2200 63 64 62 AME3-5SAZ 90-305/47-440 130-430 -40 to +80 5 600 1100 67 67 65 AME3-12SAZ 90-305/47-440 130-430 -40 to +80 12 250 680 75 73 70 AME3-15SAZ 90-305/47-440 130-430 -40 to +80 15 200 560 78 74 71 AME3-24SAZ 90-305/47-440 130-430 -40 to +80 24 125 470 81 81 80 AME3-3.3SBAZ 90-528/47-440 130-745 -40 to +80 3.3 700 2200 61 61 60 54 AME3-5SBAZ 90-528/47-440 130-745 -40 to +80 5 600 1100 67 67 66 60 AME3-12SBAZ 90-528/47-440 130-745 -40 to +80 12 250 680 72 72 70 61 AME3-15SBAZ 90-528/47-440 130-745 -40 to +80 15 200 560 72 71 70 61 AME3-24SBAZ 90-528/47-440 130-745 -40 to +80 24 125 470 71 71 69 62 Input Specifications Parameters Conditions Typical Maximum Units 115 VAC 80 mA 230 VAC 40 mA Current (full load) 277 VAC 35 mA 480VAC 30 mA 115 VAC 10 A 230 VAC 15 A Inrush current <2ms (cold start) 277 VAC 20 A 480 VAC 30 A Leakage current 0.15 mA External fuse Recommended slow blow type 1 A Input Dissipation (No Load) 0.3 W Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy Full load (typical)* 5 % Line regulation LL-HL, Full Load 3 % Load regulation (single output) 0-100% load (typical)* 5 % Transient Recovery Time 200 s Transient Response Deviation 25% load step 2 % of Vout Minimum load 0 % 3.3/5 VDC With 560F E/C 200 mV p-p Ripple & Noise 12/15 VDC With 220F E/C 400 mV p-p 24 VDC With 220F E/C 500 mV p-p *Ripple & Noise measured at 20MHz bandwidth with 0.1F and 115/230/277/480VAC (Typical input ) with Full Load Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation Resistance >1000 M www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.I 1 of 3 North America only Series AME3-AZ 3Watt AC-DC Converter General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100 KHz Over Load protection Auto recovery >125% Short circuit protection Auto recovery AME3-xxSBAZ derating at 50C o Operating temperature -40 to +80 C AME3-xxSAZ derating at 55C o Storage temperature -40 to +85 C o Maximum Case temperature 100 C Humidity Non condensing 20~95 % RH Case material Plastic resin + Fiberglass (flammability to UL 94V-0) Weight 25 g Dimensions (L x W x H) 1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm) o > 400 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus, CE, CB, FCC Information technology Equipment IEC/EN/UL 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B (* see note) Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Standards Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity (1KV) IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 FCC part 15 Subpart B, Class B, ANSI C63.4 :2003 * Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close as possible to the input of the power supply itself Pin Out Specifications* Pin Single 1* AC Input (N) or (L1) 2* AC Input (L) or (L2) 3 -V Output 4 +V Output * Note: Input Pins 1 and 2 can be N and respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be L1 andL2 respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.I 2 of 3 North America only