Click on Series name for product info on aimtec.com
Series AME3-AZ
3Watt | AC-DC Converter
FEATURES:
I/O Isolation 3000VAC RoHS compliant
o o
Operating Temp: -40 Cto +80 C Energy Star compliant
Over load, Short Circuit Protection Ultra-small package
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Models
Single output
Maximum Efficiency
Input Input Temperature Output Output
capacitive Full load (%)
Model Voltage Voltage range Voltage Current max
Load
115 230 277 480
(VAC/Hz) (VDC) (C) (V) (mA)
VAC VAC VAC VAC
(F)
AME3-3.3SAZ 90-305/47-440 130-430 -40 to +80 3.3 900 2200 63 64 62
AME3-5SAZ 90-305/47-440 130-430 -40 to +80 5 600 1100 67 67 65
AME3-12SAZ 90-305/47-440 130-430 -40 to +80 12 250 680 75 73 70
AME3-15SAZ 90-305/47-440 130-430 -40 to +80 15 200 560 78 74 71
AME3-24SAZ 90-305/47-440 130-430 -40 to +80 24 125 470 81 81 80
AME3-3.3SBAZ 90-528/47-440 130-745 -40 to +80 3.3 700 2200 61 61 60 54
AME3-5SBAZ 90-528/47-440 130-745 -40 to +80 5 600 1100 67 67 66 60
AME3-12SBAZ 90-528/47-440 130-745 -40 to +80 12 250 680 72 72 70 61
AME3-15SBAZ 90-528/47-440 130-745 -40 to +80 15 200 560 72 71 70 61
AME3-24SBAZ 90-528/47-440 130-745 -40 to +80 24 125 470 71 71 69 62
Input Specifications
Parameters Conditions Typical Maximum Units
115 VAC 80 mA
230 VAC 40 mA
Current (full load)
277 VAC 35 mA
480VAC 30 mA
115 VAC 10 A
230 VAC 15 A
Inrush current <2ms (cold start)
277 VAC 20 A
480 VAC 30 A
Leakage current 0.15 mA
External fuse Recommended slow blow type 1 A
Input Dissipation (No Load) W
0.3
Output Specifications
Parameters Conditions Typical Maximum Units
Voltage accuracy* Full load 5 %
Line regulation LL-HL, Full Load 3 %
Load regulation* 0-100% load 5 %
Transient Recovery Time 200 s
Transient Response Deviation 25% load step 2 % of Vout
Minimum load 0 %
Ripple & Noise* 20 MHz Bandwidth, 0.1F & 220F E/C in parallel 200 mV p-p
*Measured at 115/230/277/480VAC (Typical input) with Full Load
Isolation Specifications
Parameters Conditions Typical Rated Units
Tested I/O voltage 60 sec 3000 VAC
Isolation Resistance >1000 M
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 1 of 4 North America only Series AME3-AZ
3Watt | AC-DC Converter
General Specifications
Parameters Conditions Typical Maximum Units
Switching frequency 100 KHz
Over Load protection Auto recovery >125%
90-305VAC input models Continuous, Auto-recovery
Short circuit protection
90-528VAC input models Momentary, 3 sec
AME3-xxSBAZ derating at 45C
o
Operating temperature -40 to +80 C
AME3-xxSAZ derating at 50C
o
Storage temperature -40 to +85 C
o
Maximum Case temperature 100 C
Cooling Natural Convection*
Humidity Non condensing 20~95 % RH
Case material Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight 25 g
Dimensions (L x W x H) 1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
o
> 400 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, typical input voltages
115/230/277/480 VAC and at rated output load unless otherwise specified.
* Sufficient air space around is needed.
Environment Approval
Parameters Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Vibrations
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals cULus, CE, CB, FCC
Information technology Equipment IEC/EN/UL 60950-1:2006+A11:2009
EMI - Conducted and radiated emission EN55022, class B (* see note)
Harmonic Current Emissions IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity IEC 61000-4-2
RF, Electromagnetic Field Immunity IEC 61000-4-3
Standards
Electrical Fast Transient/Burst Immunity IEC 61000-4-4
Surge Immunity (1KV) IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
RF, Conducted Disturbance Immunity IEC 61000-4-6
Power frequency Magnetic Field Immunity IEC 61000-4-8
Voltage dips, Short Interruptions Immunity IEC 61000-4-11
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and
AC N as close as possible to the input of the power supply itself.
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 2 of 4 North America only