Click on Series name for product info on aimtec.com Series AME40-CJZ 40 Watt AC-DC / DC-DC Converter Picture coming soon FEATURES: I/O Isolation 3000VAC Continuous Short circuit protection Operating Temp: -40 C to +70 C Low no load consumption 0.5W Input: 85-264VAC/47-440Hz, or 100-370VDC Efficiency up to 84% Over current, Over Voltage Protection Output Voltage adjustment Models Single output Maximum Output Output Efficiency Input Voltage Input Voltage capacitive Model Voltage Current max 230VAC (VAC/Hz) (VDC) Load (V) (A) (%) (F) AME40-3.3SCJZ 85-264/47-440 100-370 3.3 8 60,000 78 AME40-5SCJZ 85-264/47-440 100-370 5 8 40,000 82 AME40-9SCJZ 85-264/47-440 100-370 9 4.44 12,000 84 AME40-12SCJZ 85-264/47-440 100-370 12 3.33 9000 84 AME40-15SCJZ 85-264/47-440 100-370 15 2.66 7000 84 AME40-24SCJZ 85-264/47-440 100-370 24 1.66 2000 84 Models Dual output Maximum Output Output Efficiency Input Voltage Input Voltage capacitive Model Voltage Current max 230VAC (VAC/Hz) (VDC) Load (V) (A) (%) (F) AME40-5DCJZ 85-264/47-440 100-370 5 4 12,000 82 AME40-12DCJZ 85-264/47-440 100-370 12 1.66 4400 84 AME40-15DCJZ 85-264/47-440 100-370 15 1.33 1000 84 Models Asymmetric Separated Dual output Maximum Output Output Efficiency Input Voltage Input Voltage capacitive Model Voltage Current max 230VAC (VAC/Hz) (VDC) Load (V) (A) (%) (F) AME40-512DCJZ 85-264/47-440 100-370 5/12 5/1.25 10,000/470 82 AME40-524DCJZ 85-264/47-440 100-370 5/24 5/0.625 10,000/400 82 Input Specifications Parameters Conditions Typical Maximum Units 115 VAC 1 A Current (full load) 230 VAC 0.6 A 115 VAC 30 A Inrush current <2ms (cold start) 230 VAC 50 A Output Specifications Parameters Conditions Typical Maximum Units Single, Dual and Main Dual Asymmetrical 2 % output Voltage accuracy Auxiliary Dual Asymmetrical output 5 % Single, Dual and Main Dual Asymmetrical 0.5 % Line regulation output Auxiliary Dual Asymmetrical output 1.5 % www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 1 of 7 North America only Series AME40-CJZ 40 Watt AC-DC / DC-DC Converter Output Specifications (continued) Parameters Conditions Typical Maximum Units Load regulation (single output) 0-100% load 1 % Load Regulation (dual output) 10-100% Balanced load 2 % 25-100% Balanced load, main output 2 % Load Regulation (asymmetric separated output) 25-100% Balanced load, auxiliary output 5 % Cross regulation (dual output) 5 8 % Cross regulation (asymmetric Main output 1 % separated output) Auxiliary output 7 % Ripple & Noise 50 100 mV p-p 115VAC, 20MHz bandwidth 15 ms Hold-up time 230VAC, 20MHz bandwidth 80 ms Voltage adjustment range Single output only 10 % of Vout Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation voltage between Main and Auxiliary 60 sec 500 VAC output Isolation Resistance >1000 M General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class II Over current protection 110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery o Operating temperature See derating curve -40 to +70 C o Storage temperature -40 to +85 C o Maximum Case temperature 100 C o Temperature coefficient 0.02 % / C Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 225 g Dimensions (L x W x H) 3.5 x 2.5 x 0.98 inches 89.0 x 63.5 x 25.0 mm o MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals cULus, CE (single output models only) Information technology Equipment IEC/EN/UL 60950-1 EMI - Conducted and radiated emission EN55022, class B Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 3 Standards Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 3 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 3 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Class 2 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 2 of 7 North America only