AMED120-JZ AC-DC Converter Click to ORDER AMED120-JZ samples The new AMED120-JZ is a brand-new AC/DC converter that offers much greater cost effectiveness due to material normalization and production automation also leading to improved reliability and performance. Offering a commercial input voltage range of 85-264VAC and an output voltage range from 12-48V, this series will offer many benefits to your new system design. This new series offers great operating temperatures, from -20C to 60C also features an isolation of 4000VAC for improved reliability and system safety. Furthermore, a higher MTBF of 300,000h, output short circuit protection (OSCP), output over-current protection (OCP), over temperature protection (OTP) and an output over-voltage protection (OVP) come standard with the series. The AMED120-JZ is perfect for electric distribution box, grid power, instrumentation, DIN Rail industrial controls, building automation applications. Features Summary AMED120-JZ Universal Input: 90 - 264VAC/127 - 370VDC 528 48 120 Operating Temp: -20 C to +60 C 4000 High isolation voltage: 4000VAC 85 70 Low ripple & noise, 150mV(p-p), max. 264 Output short circuit, over-current, over-voltage, 60 40 over-temperature protection 12 1000 90 3.3 1 0 -10 -20 -25 -40 Input voltage Output voltage Isolation Power Temp. range Derating (VAC) (V) (VAC) (W) (C) (C) Applications Training Press Release Coming Soon Power Grid Industrial Telecom Instrumentation Application Notes Product Training Video (click to open) F 052e R4 www.Aimtec.com 1 REV: 05/22/A AMED120-JZ AC-DC Converter Models & Specifications Single Output Input Max Output Output Output Maximum Efficiency Input Voltage Model Voltage wattage Voltage Current max capacitive 230VAC (VAC/Hz) (VDC) (W) (V) (A) load (F) Typ. (%) AMED120-12SJZ 90~264/47~63 127~370 120 12 10 3000 85 AMED120-24SJZ 90~264/47~63 127~370 120 24 5 1200 88 AMED120-48SJZ 90~264/47~63 127~370 120 48 2.5 800 89 Input Specifications Parameters Conditions Typical Maximum Units 115VAC 2.7 A Input Current 230VAC 1.6 A 115VAC, cold start 30 A Inrush Current 230VAC, cold start 55 A Leakage Current 240VAC <1.0 mA Output Specifications Parameters Conditions Typical Maximum Units 0 - 100% load, 12 VDC Output 2 % Voltage accuracy 0 - 100% load, 24,48 VDC Output 1 % Line regulation Rated load 0.5 % Load regulation 0 - 100% load 1 % 12 VDC Output 100 mV p-p Ripple & Noise* 24 VDC Output 120 mV p-p 48 VDC Output 150 mV p-p 115VAC 8 ms Hold up time 230VAC 16 ms 12 VDC Output 12 - 14 V Voltage adjustable range 24 VDC Output 24 - 28 V 48 VDC Output 48 - 53 V * Ripple and Noise are measured at 20MHz bandwidth. Please refer to the application not for specific details. Measured with a 47F electrolytic capacitor and a 0.1F ceramic capacitor. Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 60 sec, Leakage current < 10mA 4000 VAC Tested Input to GND voltage 60 sec, Leakage current < 10mA 2000 VAC Tested Output to GND voltage 60 sec, Leakage current < 10mA 500 VAC Insulation resistance 500VDC >100 M F 052e R4 www.Aimtec.com 2 REV: 05/22/A