AMED150-NZ AC-DC Converter Click to ORDER AMED150-NZ samples The AMED150-NZ is a whole new DIN rail bracket AC-DC converter series featuring a cost effective, energy efficient solution. The products offer a high level of stability and immunity to noise, compliant with international IEC/EN/UL62368 and IEC61558 standards. These lightweight AC-DC converters also have an extremely compact design for space saving and are ideal for applications such as industrial control equipment machinery and numerous applications for harsh environments. This new series offers great operating temperatures, from -30 to 70 and an isolation of 4000VAC for improved reliability and system safety. Furthermore, a high MTBF of 300,000h, output short circuit protection (OSCP), output over-current protection (OCP), output over-voltage protection (OVP) and an over-temperature DIN Rail protection come standard with the series. Features Summary AMED150-NZ Universal Input: 85 - 264VAC/120 - 370VDC 528 48 200 Operating Temp: -30 C to +70 C 4000 High isolation voltage: 4000VAC 154 85 85 136 Low ripple & noise, 150mV(p-p), max. 70 Output short circuit, over-current, over-voltage, 264 over temperature protection 45 12 Overvoltage category III (OVC III) 1000 85 3.3 1 0 -30 -30 -40 -40 Input voltage Output voltage Isolation Power Temp. range Derating (VAC) (V) (VAC) (W) (C) (C) Applications Training Press Release Coming Soon Power Grid Industrial Telecom Instrumentation Application Notes Product Training Video (click to open) F 052e R4 www.Aimtec.com 1 AMED150-NZ AC-DC Converter Models & Specifications Single Output Input Max Output Output Output Maximum Efficiency Input Voltage Model Voltage wattage Voltage Current max capacitive 230VAC (VAC/Hz) (VDC) (W) (V) (mA) load (F) Typ. (%) AMED150-12SNZ 85~264/47~63 120~370 135.6 12 11.3 10000 89 AMED150-15SNZ 85~264/47~63 120~370 142.5 15 9.5 8000 89.5 AMED150-24SNZ 85~264/47~63 120~370 150 24 6.25 5000 91.5 AMED150-48SNZ 85~264/47~63 120~370 153.6 48 3.2 2400 91 Input Specifications Parameters Conditions Typical Maximum Units 115VAC 3000 mA Input Current 230VAC 1800 mA 115VAC 35 A Inrush Current 230VAC 70 A Leakage Current 240VAC / 50Hz 0.5 mA RMS Output Specifications Parameters Conditions Typical Maximum Units 0 - 100% load, 12 VDC Output 2 Voltage accuracy 0 - 100% load, others 1 % Line regulation Rated load 1 % Load regulation 0 - 100% load, 230VAC 1 % 20MHz bandwidth, 12 VDC Output 100 mV p-p 20MHz bandwidth, 15 VDC Output 120 mV p-p Ripple & Noise * 20MHz bandwidth, 24 VDC Output 150 mV p-p 20MHz bandwidth, 48 VDC Output 150 mV p-p 115VAC 12 ms Hold up time 230VAC 30 ms Start up time Room temperature 0.5 0.8 S 230VAC, 12 / 15 /24 VDC Output 0.3 W No load power consumption 230VAC, 48 VDC Output 0.4 W 12 VDC Output 10.8 - 13.8 V 15 VDC Output 13.5 - 18.0 V Voltage adjustable range 24 VDC Output 21.6 - 29.0 V 48 VDC Output 43.2 52.8 V * Ripple and Noise are measured at 20MHz bandwidth. Please refer to the application not for specific details. Measured. Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 60 sec, Leakage current < 5mA 4000 VAC F 052e R4 www.Aimtec.com 2