Click on Series name for product info on aimtec.com Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter FEATURES: I/O Isolation 3000VAC Energy Star compliant o o Operating Temp: -40 C to +80 C Ultra small package Over load and, Over Voltage Protection Up to 81% efficiency Input: 90-305VAC, 47-440Hz, or 130-430VDC Short Circuit Protection Models CB Single output Max Efficiency Input Output Maximum (%) Input Voltage Output Output Model Voltage Current capacitive (VAC/Hz) wattage Voltage(V) 115 230 277 (VDC) max (A) load (F) VAC VAC VAC (W) AMEL20-3.3SAZ 90-305/47-440 130-430 13.2 3.3 4 5600 73 73 72 AMEL20-5SAZ 90-305/47-440 130-430 20 5 4 4700 77 77 76 AMEL20-12SAZ 90-305/47-440 130-430 20 12 1.66 3300 80 80 80 AMEL20-15SAZ 90-305/47-440 130-430 20 15 1.33 2200 81 80 80 AMEL20-24SAZ 90-305/47-440 130-430 20 24 0.84 1000 79 80 79 Note: Optional mounting plate version can be order by adding -ST suffix to part number (ex. AMEL20-5SMAZ-ST) Input Specifications Parameters Conditions Typical Maximum Units 115 VAC 460 mA Current (full load) 230 VAC 290 mA 277 VAC 260 mA 115 VAC 30 A Inrush current <2ms (cold start) 230 VAC 50 A 277 VAC 55 A Leakage current 0.25 mA External fuse Recommended slow blow type 1.5 A 0.5 Input dissipation (115/230/277 VAC) W Start-up time 150 ms Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Line regulation (LL-HL) 1 % Load regulation 0-100% load 2 % Transient recovery time 500 s Transient response deviation 25% load step 2 % of Vout Ripple & Noise* 200 mV p-p Hold-up time 10 ms *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1 F (M/C) and 47F (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation resistance >1000 M General Specifications Parameters Conditions Typical Maximum Units Switching frequency 65 KHz Over load protection Foldback 130 % Over voltage protection Zener Diode Clamp www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.H 1 of 5 North America only Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units Short circuit protection Auto recovery o Operating temperature With derating over 50C Refer to Chart C o Maximum case temperature 100 C o Storage temperature -45 to +95 C o Temperature coefficient 0.02 % / C Cooling Free air convection Humidity Non condensing 20 ~ 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 70 g Dimensions (L x W x H) 56.48 x 30.86 x 25.10mm (2.22 x 1.21 x 0.99 inches) o > 400 000 hrs (MIL-HDBK -217F, t=+25 C)/ Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. Environment Approval Test Parameters Conditions Wave form Half sine wave Acceleration amplitude 5gn Shock Bump duration 30ms Converter operation before and after test, body mounted (on chassis) Number of bumps 18 (3 in each direction for every axis) Test mode Sweep sine, 10-100Hz, speed 0.05Hz/s Displacement 1mm Vibration Acceleration 3g, 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals CE, UL, FCC, CB nd Information Technology Equipment UL 60950-1: 2 Edition nd Information Technology Equipment CAN/CSA-C22.2 No.60950-1-07, 2 Edition EN55022, class B EMI - Conducted and radiated emission EN55024: 2010 Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, :2008 Electrostatic Discharge Immunity IEC 61000-4-2: 2008 Standards RF, Electromagnetic Field Immunity IEC 61000-4-3: 2006 + A1: 2007 + A2:2010 Electrical Fast Transient/Burst Immunity IEC 61000-4-4: 2012 Surge Immunity IEC 61000-4-5: 2005 RF, Conducted Disturbance Immunity IEC 61000-4-6: 2008 Power frequency Magnetic Field Immunity IEC 61000-4-8: 2009 Voltage dips, Short Interruptions Immunity IEC 61000-4-11: 2004 47 CFR Part 15 Subpart B, ICES-003 Iss. 5-2012, FCC ANSI C63.4-2009 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.H 2 of 5 North America only