Click on Series name for product info on aimtec.com Series AMEL5-AZ 5 Watt AC-DC / DC-DC Converter FEATURES: I/O Isolation 3000VAC RoHS compliant o o Operating Temp: -40 C to +95 C Energy Star compliant Input: 90-305VAC, 47-440Hz, or 130-430VDC Efficiency up to 76% Over load, Over Voltage, Short Circuit Protection Soft start Models Single output Maximum Efficiency Input Input Temperature Output Output (%) capacitive Model Voltage Voltage range Voltage Current Load 115 230 277 (VAC/Hz) (VDC) (C) (V) max (A) VAC VAC VAC (F) AMEL5-3.3SAZ 90-305/47-440 130-430 -40 to +95 3.3 1. 5 2200 71 71 69 AMEL5-5SAZ 90-305/47-440 130-430 -40 to +95 5 1 1100 72 73 72 AMEL5-12SAZ 90-305/47-440 130-430 -40 to +95 12 0.42 680 75 76 76 AMEL5-15SAZ 90-305/47-440 130-430 -40 to +95 15 0.333 330 75 75 73 AMEL5-24SAZ 90-305/47-440 130-430 -40 to +95 24 0.21 220 75 76 75 Note: 1. Optional mounting plate version can be ordered by adding -ST suffix to part number (ex. AMEL5-5SAZ-ST) 2. Optional version with incorporated filter for Earth to Ground connection can be ordered by adding G to the model suffix (ex. AMEL5-5SGAZ). Input Specifications Parameters Conditions Typical Maximum Units 115 VAC 120 mA Current (full load) 230 VAC 80 mA 277 VAC 70 mA 115 VAC 15 A Inrush current <2ms (cold start) 230 VAC 30 A 277 VAC 40 A Leakage current 0.2 mA External fuse Recommended slow blow type 1.5 A Input dissipation (110/230/277 VAC) W 0.2 Start-up time 115 VAC/ Full Load 150 ms Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Line regulation 1 % Load regulation 0-100% load 1 % Transient recovery time 200 s Transient response deviation 25% load step 2 % of Vout 3.3/5V models 75 mV p-p Ripple & Noise* 12/15V models 100 mV p-p 24V models 150 mV p-p Hold-up time 5 ms *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1F (M/C) and 47F (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation Resistance >1000 M www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.O 1 of 5 North America only Series AMEL5-AZ 5 Watt AC-DC / DC-DC Converter General Specifications Parameters Conditions Typical Maximum Units Switching frequency 66 KHz Over load protection Foldback 130 % Over voltage protection Zener Diode Clamp Short circuit protection Auto recovery o Operating temperature With derating over 60C, see chart Refer to model application C o Storage temperature -40 to +95 C o Maximum case temperature 100 C o Temperature coefficient 0.02 % / C Cooling Free air convection Humidity Non condensing 20 ~ 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 30 g Dimensions (L x W x H) 51.50 x 28.00 x 17.80mm (2.03 x 1.10 x 0.70inches) o > 400,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Test Parameters Conditions Wave form Half sine wave Acceleration amplitude 5gn Shock Bump duration 30ms Converter operation Before and after test, body mounted (on chassis) Number of bumps 18 (3 in each direction for every axis) Test mode Sweep sine, 10-100Hz, speed 0.05Hz/s Displacement 1mm Vibrations Acceleration 3g, 3 loops 30min one cycle, 3h total, every axis tested Converter operation Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus for all models CE, CB (not including suffix GAZ models) Information technology Equipment IEC EN UL 60950-1 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Air level 3, Contact level 2 Standards RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 2 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.O 2 of 5 North America only