AMEL60-JZ AC-DC Converter Click to ORDER AMEL60-JZ samples The new AMEL60-JZ is a AC/DC converter that offers much greater cost effectiveness due to material normalization and production automation also leading to improved reliability and performance. Offering a commercial input voltage range of 85-264VAC and an output voltage range from 5-48V, this series will offer many benefits to your new system design. This new series offers great operating temperatures, from -40 to 70, also features an isolation of 4000VAC for improved reliability and system safety. Furthermore, a higher MTBF of 300,000h, output short circuit protection (OSCP), output over-current protection (OCP) and an output over-voltage protection (OVP) come standard with the series. The AMEL60-JZ is perfect for grid power, LED, instrumentation, industrial controls, Encapsulated communication and civil applications. Features Summary AMEL60-JZ Universal Input: 85 - 264VAC/100 - 370VDC 528 48 60 Operating Temp: -40 C to +70 C 4000 High isolation voltage: 40 00VAC 50 Low ripple & noise, 120mV(p-p), Max. 85 70 Output short circuit, over-current, over-voltage 70 264 50 protection Regulated Output 1000 85 5 3.3 1 0 -25 -40 -40 Input voltage Output voltage Isolation Power Temp. range Derating (VAC) (V) (VAC) (W) () () Applications Training Press Release Coming Soon Industrial Telecom Instrumentation Power Grid Application Notes Product Training Video (click to open) F 052e R4 www.Aimtec.com 1 REV: 04/21/A AMEL60-JZ AC-DC Converter Models & Specifications Single Output Input Input Max Output Output Output Maximum Efficiency Model Voltage Voltage wattage Voltage Current max capacitive 230VAC (VAC/Hz) (VDC) (W) (V) (A) load (F) (%) AMEL60-5SJZ 85-264/47-63 100-370 50 5 10 20000 84 AMEL60-12SJZ 85-264/47-63 100-370 60 12 5 4000 87 85-264/47-63 100-370 60 15 4 3000 88 AMEL60-15SJZ AMEL60-24SJZ 85-264/47-63 100-370 60 24 2.5 1800 89 AMEL60-48SJZ 85-264/47-63 100-370 60 48 1.25 470 90 Note: Use suffix ST for chassis and suffix STD for DIN-Rail mounting (ex. AMEL60-5SJZ-ST is chassis mounting and AMEL60-5SJZ-STD is DIN- Rail mounting version). Input Specifications Parameters Conditions Typical Maximum Units 115VAC 1.8 A Current 230VAC 1 A 115VAC 45 A Inrush current 230VAC 90 A 240VAC/50Hz 0.25 mA (RMS) Leakage current External fuse slow blow type,250V 3.15 A Output Specifications Parameters Conditions Typical Maximum Units Full load 2 % Voltage accuracy Full load 0.5 % Line regulation 0-100% load 1 % Load regulation 20MHz bandwidth 120 mV p-p Ripple & Noise* 115VAC 8 ms Hold up time 230VAC 65 ms * Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit. Isolation Specifications Parameters Conditions Typical Rated Units 60 sec, leakage current < 5mA 4000 VAC Tested I/O voltage General Specifications Parameters Conditions Typical Maximum Units Class II Safety class Over current protection Auto recovery 110 % of Iout 5V Vout, Voltage clamp or hiccup 9 VDC Over voltage protection 12V Vout, Voltage clamp or hiccup 16 VDC 15V Vout, Voltage clamp or hiccup 25 VDC F 052e R4 www.Aimtec.com 2 REV: 04/21/A