AMEOF65-JZ AC-DC Converter Click to ORDER AMEOF65-JZ samples The AMEOF65-JZ series is one of Aimtecs compact size open frame 65W AC/DC converter. It features universal AC input of 85 264VAC and at the same time accepts a DC input voltage range of 100 370VDC. Furthermore, the AMEOF65- JZ has a low power consumption, high efficiency up to 87%, high reliability and reinforced isolation of 3000VAC. It offers agency approvals UL 62368-1 and an EMC compliance of IEC/EN61000-4 and CISPR32/EN55032 and meets IEC/EN 62368-1 standards. The converters also include output short circuit, over-current & over-voltage protection. These converters are widely used in industrial, office and civil applications such as modems, printers and telecom devices. For extremely harsh EMC environments, Open Frame we recommend using the Typical Application Circuit on this datasheet. Features Summary AMEOF65-JZ 528 85 Universal Input: 85 - 264VAC/100 - 370VDC 4000 Operating Temp: -25 C to +70 C 65 High isolation voltage: 3000VAC 85 48 3000 50 Low ripple & noise, 150mV(p-p), typ. 50 70 Output short circuit, over-current, over-voltage 264 40 protection Regulated Output 1000 85 5 Open frame 1 3.3 -25 -40 Input voltage Output voltage Isolation (VAC) Power (W) Temp. range Derating () (VAC) (V) () Applications Training Press Release Coming Soon Power Grid Industrial Telecom Instrumentation Application Notes Product Training Video (click to open) F 052e R4 www.Aimtec.com 1 REV: 07/20/A AMEOF65-JZ AC-DC Converter Models & Specifications Single Output Input Input Max Output Output Output Maximum Efficiency Model Voltage Voltage Voltage Current max capacitive 230VAC wattage (W) (VAC/Hz) (VDC) (V) (A) load (F) Typ. (%) AMEOF65-5SJZ 85-264/47-63 100-370 50 5 10 40,000 80 AMEOF65-9SJZ 85-264/47-63 100-370 60 9 6.6 12,000 83 AMEOF65-12SJZ 85-264/47-63 100-370 65 12 5.42 8,000 85 AMEOF65-15SJZ 85-264/47-63 100-370 65 15 4.34 7,000 85 AMEOF65-24SJZ 85-264/47-63 100-370 65 24 2.71 1,500 87 AMEOF65-48SJZ 85-264/47-63 100-370 65 48 1.36 1,000 87 Input Specifications Parameters Conditions Minimum Typical Maximum Units 115VAC 1.6 A Input current 230VAC 0.9 A 115VAC 35 A Inrush current 230VAC 50 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Line regulation Full load 0.5 % Load regulation 5-100% load 1 % Ripple & Noise* 20MHz bandwidth 150 mV p-p Hold up time 230VAC 35 ms * Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec, leakage current < 5mA 3000 VAC General Specifications Parameters Conditions Typical Maximum Units Protection class Class II Over Current protection Auto recovery 120 300 % of Iout 5V Vout 9 9V Vout 16 12V Vout 20 Over voltage protection VDC 15V Vout 24 24V Vout 35 48V Vout 60 Short circuit protection Hiccup, Continuous F 052e R4 www.Aimtec.com 2 REV: 07/20/A