Click on Series name for product info on aimtec.com Series AMES15-MAZ 15 Watt AC-DC / DC-DC Converter FEATURES: Screw Terminals on Input & Output RoHS compliant Operating temperature: -40 to +80C Soft start Over load, Over Voltage, Short Circuit Protection Energy Star compliant Optional DIN Rail mounting bracket CE, cULus, CB approvals Universal input: 90-264VAC, 47-440Hz 4000VAC I/O Isolation CB Models Single output Maximum Efficiency Max Input Output Output Input Voltage Output Capacitive (%) Model voltage Voltage Current (VAC/Hz) Load wattage 115 230 (VDC) (V) max (A) VAC VAC (W) (F) AMES15-3.3SMAZ 90-264/47-440 130-370 9.9 3.3 3 4700 74 74 AMES15-5SMAZ 90-264/47-440 130-370 15 5 3 2200 75 76 AMES15-12SMAZ 90-264/47-440 130-370 15 12 1.25 1000 81 82 AMES15-15SMAZ 90-264/47-440 130-370 15 15 1 680 81 83 AMES15-24SMAZ 90-264/47-440 130-370 15 24 0.63 470 83 83 Models Dual output Maximum Efficiency Max Input Output Output Input Voltage Output Capacitive (%) Model voltage Voltage Current (VAC/Hz) Load wattage 115 230 (VDC) (V) max (A) VAC VAC (W) (F) AMES15-5DMAZ 90-264/47-440 130-370 15 5 1.5 1000 78 79 AMES15-12DMAZ 90-264/47-440 130-370 15 12 0.63 470 81 82 AMES15-15DMAZ 90-264/47-440 130-370 15 15 0.5 330 82 83 Input Specifications Parameters Conditions Typical Maximum Units 115VAC 350 mA Current (full load) 230VAC 180 mA 115 VAC 10 A Inrush current <2ms (cold start) 230 VAC 20 A 115 VAC 0.1 mA Leakage current 264 VAC 0.2 mA External Fuse (recommend)slow blow type 2 A Input Dissipation (110/230Vac) W 0.2 Under Voltage Protection 85 VAC Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 2 % Line regulation LL-HL 1 % Load regulation (single output) 0-100% 1 % st nd Cross regulation (dual output) 25% load - 1 out, 100% load 2 out 5 % Transient Recovery Time 300 s Transient Recovery Deviation 25% load step 2 % of Vout 3.3/5V models 75 Ripple & Noise* 12/15V models 100 mVp-p 24V models 150 Hold-up time min 20 ms * Ripple and Noise are measured at 20MHz bandwidth by using 0.1 F (M/C) and 47 F (E/C) parallel capacitor. www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 1 of 5 North America only Series AMES15-MAZ 15 Watt AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 VAC Isolation resistance >1000 M General Specifications Parameters Conditions Typical Maximum Units Switching frequency 132 KHz Protection class Class II Start up time 350 mS Over load protection Foldback >130 % Over voltage protection Zener diode clamp Short circuit protection Auto recovery Case material Metal o o Operating temperature With derating over 55 C (10CFM) -40 to +80 C o Storage temperature -50 to +100 C o Max Case temperature 100 C o Temperature coefficient 0.02 % / C Cooling Free air convection Humidity 95 % RH Weight 100 g Dimensions (L x W x H) 3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm o > 400,000hrs (MIL-HDBK -217F, t=+25 C) MTBF > 100,000hrs (MIL-HDBK -217F, t=at highest operating temperature) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals cULus, CE, CB IEC EN UL 60601-1, 2 x MOOP, CSA-C22.2 No. Medical Electrical Equipment 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 Standards RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 2 of 5 North America only