Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 3480/18C Construction Diameters (In) 1) Component 1 18 X 1 PAIR a) Conductor 28 (7/36) AWG TC 0.015 b) Insulation 0.010 Wall, Nom. PVC, Semi Rigid 0.035 (1) Color Code Alpha Wire Color Code A Pair Color Pair Color Pair Color BLACK- 1 BLACK-RED 7 13 RED-ORANGE ORANGE 2 BLACK-WHITE 8 RED-GREEN 14 GREEN-BLUE 3 BLACK-GREEN 9 RED-WHITE 15 GREEN-WHITE 4 BLACK-BLUE 10 RED-BLUE 16 GREEN-BROWN GREEN- 5 BLACK-BROWN 11 RED-YELLOW 17 ORANGE GREEN- 6 BLACK-YELLOW 12 RED-BROWN 18 YELLOW c) Pair 2/Cond Cabled Together (1) Twists: 12.0 Twists/foot (min) 2) Cable Assembly 18 Components Cabled a) Twists: 2.8 Twists/foot (min) 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing Out b) Drain Wire 28 (7/36) AWG TC c) Braid TC,65% Coverage, Min. 4) Jacket 0.035 Wall, Nom.,PVC 0.389 (0.413 Max.) a) Color(s) SLATE ALPHA WIRE-* P/N 3480/18C 18PR 28 AWG b) Print SHIELDED 75C (UL) TYPE CL2 OR AWM 2464 ---LLXXXXXX CSA TYPE CMG FT4 CE ROHS * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. Applicable Specifications 80C / 300 V 1) UL AWM/STYLE 2464 RMS CL2 75C VW-1 2) CSA International CMG 60C FT4 3) CE: EU Low Voltage Directive 2006/95/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. The outer surface materials used in the manufacture of this part meet the 3) California Proposition 65: requirements of California Proposition 65. Properties Physical & Mechanical Properties 1) Temperature Range -20 to 80C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 57 Lbs, Maximum Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS