Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 35196 Construction Diameters (In) 1) Component 1 6 X 1 COND a) Conductor 22 (7/30) AWG Tinned Copper 0.030 b) Insulation 0.010 Wall, Nom. PVC, Semi Rigid 0.050 (1) Color Code Alpha Wire Color Code E Cond Color Cond Color Cond Color 1 BLACK 3 RED 5 YELLOW 2 BROWN 4 ORANGE 6 GREEN 2) Cable Assembly 6 Components Cabled a) Twists: 5.3 Twists/foot (min) Components to be arranged from b) Orientation: INSIDE LAYER to OUTSIDE LAYER c) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing In b) Drain Wire 22 (7/30) AWG Tinned Copper 4) Jacket 0.032 Wall, Nom.,Polyethylene (PE) 0.222 (0.234 Max.) a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White b) Ripcord 1 End 810 Denier Nylon ALPHA WIRE-* P/N 35196 6C 22 AWG XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS c) Print (SEQ FOOTAGE) * = Factory Code Applicable Specifications 1) CE: EU Low Voltage Directive 2014/35/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. Exempt from warning labels based on the Consent Judgment. Please see 3) California Proposition 65: Alpha s CA Prop 65 Statement for more information. Properties Physical & Mechanical Properties 1) Temperature Range -30 to 80C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 38 Lbs, Maximum 4) Sunlight Resistance Yes 5) Direct Burial Yes Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS 2) Capacitance 36 pF/ft 1 kHz, Nominal Conductor to Conductor 3) Ground Capacitance 65 pF/ft 1 kHz, Nominal 4) Inductance 0.18 H/ft, Nominal 5) Conductor DCR 16.4 /1000ft 20C, Nominal 6) OA Shield DCR 11.8 /1000ft 20C, Nominal Other Packaging Flange x Traverse x Barrel (inches) a) 1000 FT 12 x 10 x 5 Continuous length