Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 45096 Construction Diameters (In) 1) Component 1 6 X 1 COND a) Conductor 24 (7/32) AWG Tinned Copper 0.024 b) Insulation 0.016 Wall, Nom. TPE 0.056 (1) Color Code Alpha Wire Color Code E Cond Color Cond Color Cond Color 1 BLACK 3 RED 5 YELLOW 2 BROWN 4 ORANGE 6 GREEN 2) Cable Assembly 6 Components Cabled a) Twists: 6.0 Twists/foot (min) Components to be arranged from INSIDE b) Orientation: LAYER to OUTSIDE LAYER c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing In b) Drain Wire 24 (7/32) AWG Tinned Copper 4) Jacket 0.042 Wall, Nom.,TPE 0.261 (0.274 Max.) a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White b) Ripcord 1 End 810 Denier Nylon ALPHA WIRE-* P/N 45096 XTRAGUARD(R) 4 RU AWM 20237/21918 125C 300V SUN RES OR CRU AWM I/II A/B 125C 300 VOLTS FT1 c) Print P-07-KA140023-MSHA CE ROHS (SEQ FOOTAGE) * = Factory Code Applicable Specifications 125C / 300 V 1) UL AWM/STYLE 20237 RMS 125C / 300 V AWM/STYLE 21918 RMS SUN RES 125C / 300 V 2) CSA International C(RU) AWM I/II A/B FT1 RMS SUN RES (Black only) PENNSYLVANIA BUREAU OF MINE SAFETY 3) Other APPROVED 4) CE: EU Low Voltage Directive 2014/35/ECEnvironmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. Exempt from warning labels based on the Consent Judgment. Please see Alpha s CA Prop 65 3) California Proposition 65: Statement for more information. Properties Physical & Mechanical Properties 1) Temperature Range -50 to 125C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 24.6 Lbs, Maximum 4) Sunlight Resistance Yes Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS 2) Capacitance 18.1 pF/ft 1 kHz, Nominal Conductor to Conductor 3) Ground Capacitance 33 pF/ft 1 kHz, Nominal 4) Inductance 0.22 H/ft, Nominal 5) Conductor DCR 26 /1000ft 20C, Nominal 6) OA Shield DCR 15.9 /1000ft 20C, Nominal Other Packaging Flange x Traverse x Barrel (inches) a) 1000 FT 12 x 12 x 3.5 Continuous length b) 500 FT 12 x 6 x 3.5 Continuous length c) Bulk(Made-to-order) Spool dimensions may vary slightly Notes: a) Print legend will contain CSA SUN RES on black cables only. www.alphawire.com Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742)