Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 45482 Construction Diameters (In) 1) Component 1 2 X 1 PAIR a) Conductor 22 (7/30) AWG Tinned Copper 0.030 b) Insulation 0.016 Wall, Nom. TPE 0.062 (1) Color Code Alpha Wire Color Code B Pair Color Pair Color Pair Color 1 WHITE-BLACK 2 WHITE-BROWN c) Pair 2/Cond Cabled Together (1) Twists: 6.9 Twists/foot (min) 2) Cable Assembly 2 Components Cabled a) Twists: 5.3 Twists/foot (min) Components to be arranged from b) Orientation: INSIDE LAYER to OUTSIDE LAYER Nonwoven Polyester Tape, 25% c) Core Wrap Overlap, Min. 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing In b) Drain Wire 22 (7/30) AWG Tinned Copper 4) Jacket 0.045 Wall, Nom.,TPE 0.301 (0.315 Max.) a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White b) Ripcord 1 End 810 Denier Nylon ALPHA WIRE-* P/N 45482 2PR 22 AWG XTRAGUARD(R) 4 (UL) TYPE PLTC 105C SUN RES OR AWM 20237/21918 125C 300 V OR c) Print CRU AWM I/II A/B 125C 300 V FT1 P-07-KA140023-MSHA CE ROHS (SEQ FOOTAGE) * = Factory Code Applicable Specifications 125C / 300 V 1) UL AWM/STYLE 20237 RMS PLTC 105C 125C / 300 V AWM/STYLE 21918 RMS SUN RES 125C / 300 V 2) CSA International C(RU) AWM I/II A/B FT1 RMS SUN RES (Black only) PENNSYLVANIA BUREAU OF MINE 3) Other SAFETY APPROVED 4) CE: EU Low Voltage Directive 2014/35/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. Exempt from warning labels based on the Consent Judgment. Please see 3) California Proposition 65: Alpha s CA Prop 65 Statement for more information. Properties Physical & Mechanical Properties 1) Temperature Range -50 to 125C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 27 Lbs, Maximum 4) Sunlight Resistance Yes Electrical Properties (For Engineering purposes only)