Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 6306 Construction Diameters (In) 1) Component 1 6 X 1 COND a) Conductor 24 (7/32) AWG TC 0.024 b) Insulation 0.010 Wall, Nom. PVC, Semi Rigid 0.044 (1) Color(s) Cond Color Cond Color Cond Color 1 BLACK 3 RED 5 BROWN 2 WHITE 4 GREEN 6 BLUE 2) Cable Assembly 6 Components Cabled a) Twists: 6.0 Twists/foot (min) 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing Out b) Drain Wire 24 (7/32) AWG TC 4) Jacket 0.032 Wall, Nom.,PVC 0.201 (0.213 Max.) a) Color(s) SLATE ALPHA WIRE-* P/N 6306 6C 24 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2464 OR C(UL) 60C TYPE CMG FT4 CE ROHS b) Print * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. Applicable Specifications 80C / 300 V 1) UL AWM/STYLE 2464 RMS CM 75C VW-1 2) CSA International C(UL) TYPE CMG 60C FT4 3) CE: EU Low Voltage Directive 2006/95/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. The outer surface materials used in the manufacture of this part meet the 3) California Proposition 65: requirements of California Proposition 65. Properties Physical & Mechanical Properties 1) Temperature Range -20 to 80C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 24.6 Lbs, Maximum Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS 2) Capacitance 32 pf/ft 1 kHz, Nominal Conductor to Conductor 3) Ground Capacitance 58 pf/ft 1 kHz, Nominal 4) Inductance 0.19 H/ft, Nominal 5) Conductor DCR 26 /1000ft 20C, Nominal 6) OA Shield DCR 15.9 /1000ft 20C, Nominal Other Packaging Flange x Traverse x Barrel (inches)