Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 6390 Construction Diameters (In) 1) Component 1 2 X 1 PAIR a) Conductor 28 (7/36) AWG TC 0.015 b) Insulation 0.010 Wall, Nom. Polyethylene(PE) 0.035 (1) Color Code Alpha Wire Color Code K Pair Color Pair Color Pair Color 1 BLACK-RED 2 BLACK-WHITE c) Pair 2/Cond Cabled Together (1) Twists: 12.0 Twists/foot (min) 2) Cable Assembly 2 Components Cabled a) Twists: 8.0 Twists/foot (min) 3) Shield: Alum/Mylar Tape, 25% Overlap, Min. a) Foil Direction Foil Facing Out b) Drain Wire 28 (7/36) AWG TC c) Braid TC,90% Coverage, Min. 4) Jacket 0.035 Wall, Nom.,PVC 0.211 (0.224 Max.) a) Color(s) SLATE ALPHA WIRE-* P/N 6390 2PR 28 AWG SHIELDED 75C (UL) TYPE CL2 OR AWM 2960 b) Print LL701765 CSA TYPE CMH 60C FT1 ROHS * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. Applicable Specifications 60C / 30 V 1) UL AWM/STYLE 2960 RMS CL2 75C VW-1 2) CSA International CMH 60C FT1 Environmental1) EU Directive 2002/95/EC(RoHS): All materials used in the manufacture of this part are in compliance with EU Directive 2002/95/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire s web site for compliance Date of Manufacture. 2) REACH Regulation (EC 1907/2006): This product does not contain any of the substances listed on the European Union REACH Substance of Very High Concern (SVHC) candidate list, dated 30 March 2010, in excess of a concentration of 0.1% weight/weight. The outer surface materials used in the manufacture of this part meet the requirements of 3) California Proposition 65: California Proposition 65. Properties Physical & Mechanical Properties 1) Temperature Range -20 to 75C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 10.8 Lbs, Maximum Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS 2) Characteristic Impedance 100 3) Mutual Capacitance 15.5 pf/ft 1 kHz, Nominal 4) Ground Capacitance 27.5 pf/ft 1 kHz, Nominal 5) Conductor DCR 66 /1000ft 20C, Nominal 6) OA Shield DCR 4.9 /1000ft 20C, Nominal Other Packaging Flange x Traverse x Barrel (inches) a) 1000 FT 12 x 10 x 5 Continuous length b) 500 FT 12 x 4.5 x 3.5 Continuous length c) 100 FT 6.5 x 4 x 2.5 Continuous length Spool dimensions may vary slightly Notes: a) CSA File Number may also be LL49185 www.alphawire.com Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742) Although Alpha Wire (Alpha) makes every reasonable effort to ensure there accuracy at the time of publication, information and specifications described herein are subject to errors or omissions and to changes without notice, and the listing of such information and specifications does not ensure product availability. Alpha provides the information and specifications herein on an AS IS basis, with no representations or warranties, whether express, statutory or implied. In no event will Alpha be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary) whatsoever, even if Alpha had been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207