Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 79246 Construction Diameters (In) 1) Component 1 4 X 1 COND a) Conductor 22 (19/34) AWG Tinned Copper 0.032 0.0095 Wall, Nom. Modified Polyphenylene b) Insulation 0.051 Ether (1) Color Code Alpha Wire Color Code D Cond Color Cond Color Cond Color 1 BLACK 3 WHITE 2 RED 4 GREEN 2) Cable Assembly 4 Components Cabled a) Twists: 8.0 Twists/foot (min) Components to be arranged from INSIDE b) Orientation: LAYER to OUTSIDE LAYER c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 3) Shield: A/P/A Tape, 25% Overlap, Min. a) Braid Tinned Copper,70% Coverage, Min. 4) Jacket 0.035 Wall, Nom.,MPPE 0.230+/- 0.011 a) Color(s) SLATE b) Jacket Separator Nonwoven Polyester Tape, 25% Overlap, Min. ALPHA WIRE-* P/N 79246 4C 22 AWG ECOFLEX(TM) RU AWM 21819 105C 600V OR 21492 c) Print 80C 300V VW-1 CLASS M C(RU) AWM I/II A/B FT1 600V 105C CE ROHS (SEQ FOOTAGE) * = Factory Code Applicable Specifications 105C / 600 V 1) UL AWM/STYLE 21819 RMS 80C / 300 V AWM/STYLE 21492 RMS VW-1 105CC / 600V V 2) CSA International C(RU) AWM I/II A/B FT1 RMS 3) Other Halogen-Free 4) CE: EU Low Voltage Directive 2014/35/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. Exempt from warning labels based on the Consent Judgment. Please see Alpha s CA Prop 65 3) California Proposition 65: Statement for more information. Properties Physical & Mechanical Properties 1) Temperature Range -40 to 105C(static), -5 to 105C (dynamic) 2) Bend Radius 6X Cable Diameter(static), 8X Cable Diameter(dynamic) 3) Pull Tension 26 Lbs, Maximum Electrical Properties (For Engineering purposes only) 600 V 1) Voltage Rating RMS 2) Capacitance 29 pF/ft 1 kHz, Nominal Conductor to Conductor 3) Ground Capacitance 52 pF/ft 1 kHz, Nominal 4) Inductance 0.17 H/ft, Nominal 5) Conductor DCR 15.3 /1000ft 20C, Nominal 6) OA Shield DCR 6.3 /1000ft 20C, Nominal Other Packaging Flange x Traverse x Barrel (inches) a) 1000 FT 12 x 10 x 5 Continuous length b) 100 FT 6.5 x 4 x 2.5 Continuous length Spool dimensions may vary slightly www.alphawire.com Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742)