IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection AC - 2 WIRE-STANDARD Overload Protection Brass, Nickel Plated (BN), Cylindrical, Wire Break Resistance Threaded, 90-250V AC, 250mA, Transient Voltage Protection LED for Output Energized Temperature Range: -25 to 70C (-13 to 158F) M30 Flush Mount M30 Non-Flush Mount Sensing Distance 10mm (.39 in.) 15mm (.59 in.) Cable or Connector Style Cat. No. Cable Cable Normally Open AIS30F10AW220-2M AIS30N15AW220-2M Normally Closed AIS30F10RW220-2M AIS30N15RW220-2M Ripple Voltage Voltage Range 90-250V 90-250V Supply Current 10mA 10mA Max. Load Current 250 mA 250 mA Voltage Drop Across Sensor 9V 9V Max. Leakage Currrent 3mA 3mA Switching Frequency 10 Hz 10 Hz Hysterisis 1.0mm 1.5mm Temperature Drift 20m/K 30m/K Repeatability 0.3mm 0.5mm Fixed Cable PVC 2m (6ft. 6in.) encapsulated oil resistant cable. For other cable lengths and/or PUR cable, please consult Altech. Supplied with brass, nickel plated locknuts. A/F 36 5 5 A/F 36 LED LED 15 60 20 80 60 100 80 100 NNoottee:: SSeennssoorr ddiimmeennssiioonnss iinn mmmm.. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908) 806-9400 Fax (908) 806-9490 24 M30x1.5 11 13.5 5 M30x1.5 11 13.5 5Metric/in. Conversion Table This table converts 1.5 mm = .06 in. 23.0 mm = .08 in. millimeters to inches 2.0 mm = .08 in. 28.0 mm = 1.10 in in reference to the 4.0 mm = .16 in 30.0 mm = 1.18 in. illustrations included 5.0 mm = .20 in. 32.0 mm = 1.26 in. on these pages. 6.0 mm = .23 in. 34.0 mm = 1.34 in. If you do not see a 8.0 mm = .31 in. 40.0 mm = 1.57 in. coverted dimension, 10.0 mm = .39 in. 50.0 mm = 1.97 in. multiply mm by 12.0 mm = .47 in. 51.0 mm = 2.01 in. 0.03937 to convert to 15.0 mm = .59 in. 60.0 mm = 2.36 in. inches. 18.0 mm = .70 in. 80.0 mm = 3.12 in. Wiring Diagrams Note: Wire colors are applicable on cables purchased from Altech Fixed Cable Fixed Cable BR BR + LOAD LOAD BL BK Yellow/GRN BL Normally Open Normally Closed Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908) 806-9400 Fax (908) 806-9490 25