CBI All in One DC UPS Power Solutions Everything and more More efficiency of the battery thanks to continuous control over time. More monitoring in main connection nodes: input, output load, battery. Event logging: number of battery charging cycles, charge cycles completed, aborted charge cycles, Ah charged, charging time, total number of transitions stand-by /back-up etc. Event Management: checking the load output, shutdown management of PCs (UPS function), RESET management of a generic equipment. Flexibility of use: customization of the entire charging curve of the battery, battery type setting, setting of the various time-out algorithms of charge, setting boost voltage, absorption, float, etc... configuration as DC-UPS or batteries charger, enabling power supply function. Power Continuity DC-UPS = Power Supply + Battery Charger + Back Up Module Double Output, Optimized Power Management. Thanks to the DC-UPS units, it will be possible to smart-manage available power. It will be automatically allocated between load and battery. Supplying power to the load is the rst priority of the unit thus it is not necessary to double the power, and also the power available for the battery will go to the load if the load requires so. Output Load: 12, 24, 48 Power Boost: In x 2 Continuous In x 3 max 4 sec. Time Buffering Time buffering is enabled when in InPower Boost mode the maximum current on the load output is the 2 back-up mode. Buffering time times the rated current (2 x In) in Load setting is possible by operating the continuous operation and 3 times rotary switch on the front panel. the rated current (3 x In) for max. 4 seconds. In In TIME BUFFERING In I batt 2 In > 4 min. In I batt I batt 3 In max. 4 sec. Smart Battery Management Load output will not be affected by battery conditions. The DC-UPS insures continuous power supply to the load even in conditions of completely discharged batteries. The automatic multi-stage operation optimizes and adapts to the battery status. DC-UPS can recharge deeply discharged batteries even when their voltage is close to zero, thus allowing Battery Load recharge and complete recovery of at batteries. Avoid Deep Battery Discharge In case of mains failure, the battery will supply the load until battery voltage reaches 1.5 Vpc Load (Volt per cell). Below this level the device automatically switches off to prevent deep discharge and battery damage. Adjustable Maximum Battery Charging Current The maximum battery charging current can be set from 10% to 100% of the device rated value. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 134CBI All in One DC UPS Power Solutions Power Continuity Start from Battery without Main If you want to restart the system while the mains is off, a battery restart function is available, via RTCONN cable connections, or via pushbutton Start from battery in the front panel. Wide input voltage range Flexibility is given also by the wide range input voltage. The range of the devices accept input voltage 120 - 230 - 277 - 400 - 500 VAC. One device for output 12 or 24 VDC You can select the voltage between 12 or 24 VDC just before installing the device in your panel (available on selected products in the new Altech DC-UPS units). Connection & Monitoring Monitor Signals Clear definition of each system oper-ation, via LED indications and Relay contact: Contact Port signals, galvanic insulation Main or back-up signaling relay with voltage-free. NO-NC output terminals. Battery faulty signaling relay, relay with voltage-free. NO-NC output terminals. Flat battery signaling relay, relay with voltage-free. NO-NC output terminals. Display Signals by LED Input Main On Off Battery Fault Low battery (capacity less than 30%) Type of Battery charge mode Help through blinking code the diagnosis of the system Driver Contact Remote link for selection of trickle/ boost charging Via RTCONN remote connections cable it is possible to drive the devices from Boost - Bulk to Trickle - Float charge. It is also possible to permanently install a jumper for Boost - Bulk Charging. Accessories Boost at charge All DC-UPS units can be made available with the following options by RJ45 or RJ11 connector: Temperature sensor Probe, for ambient temperature compensation charging. Voltage drop cable compensation. Battery Start UP cable. Auxiliary output Aux 2 andAux 3 MODBUS and CANBUS MODBUS and CANBUS connection for Multimedia management, for connection to external displays and perform customized data monitoring. Connection to: Power View App Power View Graphic Power View System Power View Bar Graph Power Bus Power View Config Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 135 Input exibility 12 VDC 24 VDC2