16 1820 1 2 3 4 5 6 7 8 9 10 12 14 GFR Series - 1 Pole+N, C Trip, 300 mA 277V AC Ground Fault Relay with Overload Protection (RCBO) The GFR Series is a combined Equipment Ground Fault Relay and Supplementary Protector (RCBO), featuring dual pole switching (live and neutral) and designed to provide protection against overloads and AC ground faults (residual current faults) as well as pulsating DC ground faults. Ordering Information Rated Type/ Rated Current Cat. No. Voltage 5.0A GFR2C05300 277V AC Ground Fault Sensing & Relaying Equipment 6.0A GFR2C06300 277V AC E483493 8.0A GFR2C08300 277V AC 10A GFR2C10300 277V AC 12A GFR2C12300 277V AC 13A GFR2C13300 277V AC 15A GFR2C15300 277V AC 16A GFR2C16300 277V AC 20A GFR2C20300 277V AC GFL Series RCBO 25A GFR2C25300 277V AC Overload Trip Curves 30A GFR2C30300 277V AC Characteristics B, C, D 32A GFR2C32300 277V AC 7200 3600 35A GFR2C35300 277V AC 2400 40A GFR2C40300 277V AC 1200 600 480 360 Technical Specification 240 Number of Poles 1+N 120 Voltage Rating (maximum) 277V AC 60 40 Ground Fault Sensitivity Level 300 mA 20 Short Circuit Withstand Rating 10 kA Rated Frequency 50/60Hz 10 Trip Characteristic C 5 2 2 Cable Size & Tightening Torque Stranded Wire: 16 - 3 AWG (1.5 mm - 25 mm ) 17.5 lb-in (2.0 Nm) 2 2 16 - 10 AWG (1.5 mm - 5.5 mm ) 17.5 lb-in (2.0 Nm) Solid Wire: 1 2 2 18 - 16 AWG (1 mm - 1.5 mm ) 25 lb-in (2.8 Nm) 0.5 Electrical Life 6000 Switching Operations Mechanical Life 10000 Switching Operations Dimensions B C D 0.1 (to convert to inches multply by 0.03937) 0.05 85mm 45mm 35 mm 0.01 1.05 1.35 Rated current multiple x I n GFR Series RCBO Ground Fault Trip Curve 0.5 0.4 0.2 0.3 0.15 0.1 0.05 17.5mm 0.04 0.03 Weight 217 g 0.02 0.015 0.01 GFR Series RCBO Short Circuit Withstand Rating V I IR Backup 0.005 0.5 1 5 0.85 1.15 20A 10kA None I 1+N Pole Class J Fuse 250A or lower In 277V AC >20A 10kA Altech L Series Branch Circuit Breaker Altech R Series Supplementary Protector 1 35 Royal Road Flemington, NJ 08822-6000 t 908-806-9400 f 908-806-9490 www.altechcorp.com UL 1077 Ground Fault Relay with Overload Protection 71mm 60mm 44mm t(s) Switch time t(s)UL 1077 Ground Fault Relay with Overload Protection GFR Series - 1 Pole+N, C Trip, 300 mA Applicable voltage systems and wiring examples. L1 GFR2 277 V 480 V 480 V L2 277 V 480 V N 277 V L3 L1 GFR2 240 V 400 V 400 V L2 240 V 400 V N 240 V L3 L1 GFR2 120 V 208 V 208 V L2 120 V 208 V N 120 V L3 GFR2 NOTE: Wiring a hot leg/phase to N terminal is not permitted. 2 35 Royal Road Flemington, NJ 08822-6000 t 908-806-9400 f 908-806-9490 www.altechcorp.com 120 V 120 V 240 V L1 N L2 LOAD LOAD LOAD LOAD 1 N LINE N 2