CircuitProtection 2016.QXD CircuitProtection 4/8/16 1:47 PM Page 62 R-Series UL1077 Recognized Supplementary Protector DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 480Y/277V AC, 50/60Hz 10kA Short Circuit Withstand Capacity Positive Trip indicator (Green - off/tripped, Red - on) Applications (on the load side of Branch Circuit Protection) include: Sensitive Electronics, Power Supplies, Appliance circuits, etc. E301611 Indicator 480Y/277VAC Voltage Rating window Short Circuit Withstand Rating 0.5-6A (RC): 10kA with no back-up fuse 8-63A (RC): 10kA with UL-listed (UL - Ratings) Class J back-up fuse 5kA with no back-up fuse ON Interrupting Capacity 0.5-63A (RC): 10kA (IEC/EN60898/60947-2) Calibration Temperature 30C (86F) OFF Operating Temperature -25 to 60C (-13 to 140F) -25 to 75C (-13 to 167F) Storage Temperature 14-3 AWG: 17.5 lb-in. (2.0 Nm) Terminal Size Acceptability Trip curve and Torque 18-16 AWG: 25 lb-in. (2.8 Nm) and amperage window display. IP20 at front Terminal Protection Degree 6,000 cycles on/off Electrical Life 10,000 cycles on/off Mechanical Life copper wire only 60/75C Wire Connection 3g (18-50Hz) Vibration Resistance Mounting Orientation In any plane short CirCuit WithstanD ratinGs for r-series suppleMentary proteCtor Backup Protection Trip Amp UL-Listed No Backup Fuse Curve Range Class J Fuse Required up to 10kA up to: All 0.5 - 6A 4xRC* 10kA All 8 - 63A 4xRC* 5kA *up to nearest rated current DC voltage rating: 48 VDC (self-certified). Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 62 Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers CircuitProtection 2016.QXD CircuitProtection 4/4/16 12:25 PM Page 63 60 40 Time 10 4 versus 1 Current Trip Curve 10 For the exact trip curve, please refer to page 67. 4 1 0.4 Dimensions in mm BCBB CC DDD side view -1 10 -2 4x10 -2 10 -3 4x10 45 (1.77 in.) -3 10 2 34 6 8 101620 Multiple of Rated Current 6.5 (0.26 in.) 44 (1.73 in.) 60 (2.36 in.) 77 (3.03 in.) 1 POlE 2 POlE 3 POlE 17.5 (0.69 in.) 35 (1.38 in.) 52.5 (2.07 in.) Trip-Characteristics* Applications Characteristic Trip Boundaries Lighting Business Wiring Control Power General Reactive Equipment Thermal Trip Magnetic Trip Protection Transformers Supplies Electronics Load Control Appliances Must not Must Trip Must not Must Trip Circuits Trip>100ms <1hr Trip>100ms at 100ms B-Characteristics 1.13xRC 1.45xRC 3xRC 5xRC C-Characteristics 1.13xRC 1.45xRC 5xRC 10xRC D-Characteristics 1.13xRC 1.45xRC 10xRC 20xRC *The value of each characteristic is shown vertically beneath its corresponding heading. Warning This information should only be used as a selection guide. The use of a Miniature Circuit Breaker/Supplementary Protector in an application with a certain Trip-Characteristic always requires prototype testing It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Supplementary Protector for his specific application. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 63 Seconds Time t Minutes 96.1 (3.80 in.) 85.5 (3.37 in.) Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers