PS-100 Series Features: Universal AC input / full range Specifications Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on No load power consumption <1W 100% full load burn-in test 3 year warranty OUTPUT Cat. No. PS-10012 PS-10015 PS-10024 DC VOLTAGE 12V 15V 24V RATED CURRENT 7.5A 6.5A 4.2A CURRENT RANGE 0 ~ 7.5A 0 ~ 6.5A 0 ~ 4.2A RATED POWER 90W 97.5W 100.8W RIPPLE & NOISE (max) 120mVp-p 120mVp-p 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. VOLTAGE ADJ. RANGE 12 ~ 15V 15 ~ 18V 24 ~ 29V VOLTAGE TOLERANCE 2.0% 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% SETUP, RISE TIME 2700ms, 80ms / 230VAC 2700ms, 80ms / 115VAC at full load HOLD UP TIME (Typ.) 50ms / 230VAC 18ms / 115VAC at full load INPUT VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC Connect AC/L(+), AC/N(-) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 87% 87% 89% AC CURRENT (max.) 3A / 115VAC 1.6A / 230VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC 45A / 230VAC PROTECTION OVERLOAD 105 ~ 135% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed Under short circuit or overload 150% conditions, output voltage may shut down for 5 sec. and then go into constant current protection mode OVERVOLTAGE 16 ~ 20V 19 ~ 23V 30 ~ 35V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 90C 15C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover ENVIRONMENT WORKING TEMP. -20 ~ +60C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03% / C (0 ~ 50C) VIBRATION 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes MOUNTING Compliance to IEC60068-2-6 SAFETY & EMC SAFETY STANDARDS UL60950-1 EN60950-1 compliant Design refer to EN50178 WITHSTAND VOLTAGE I/P-O/P: 3KVAC ISOLATION RESISTANCE I/P-O/P: 100M Ohms/500VDC (25C 70% RH) EMI CONDUCTION & RADIATION Compliance to EN61204-3 EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Harmonic current test 90% load EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 EN55024 EN61000-6-2 EN61204-3 heavy industry level criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS that it still meets EMC directives. MTBF 486K hrs min. MIL-HDBK-217K (25C) DIMENSION 100x93x56mm (WxHxD) PACKING 0.35Kg 36pcs / 13.6Kg / 0.89CUFT NOTE All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 84Mechanical Specification 56 100 47 5564.7555 7.5 27.4 Terminal Pin. No Assignment 7 Pin No. Assignment Pin No. Assignment 15AC/L ,6 -V 2 AC/N 7 LED 3,4 +V 8 +V ADJ. 3 8 Block Diagram RECTIFIER S RECTIFIERS POWE R +V EMI I/P & & SWITCHING FILTER -V FILTER FILTER DETECTION CIRCUIT PWM O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 60 40 50 20 40 -20 0 10 20 30 40 45 50 60 70 (VERTICAL ) 88 951100 11020 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz AMBIENT TEMPERATURE (C) Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 85 LOAD (%) 1 2 LOAD (%) 3 4 5 6 93 45 68