Features: High efficiency 91% and low power dissipation PS-C120 Series 150% peak load capability Built-in active PFC function, PF>0.93 Specifications Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2 (EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty Cat. No. PS-C12012 PS-C12024 PS-C12048 OUTPUT DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A RATED POWER 120W 120W 120W PEAK CURRENT 15A 7.5A 3.75A PEAK POWER 180W (3 sec.) 3 seconds max., please refer to peak loading curves RIPPLE & NOISE (max) 100mVp-p 100mVp-p 120mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. VOLTAGE ADJ. RANGE 12 ~ 14V 24 ~ 28V 48 ~ 55V VOLTAGE TOLERANCE 1.0% 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% SETUP, RISE TIME 1500ms, 60ms / 230VAC 3000ms, 60ms / 115VAC at full load HOLD UP TIME (Typ.) 20ms / 230VAC 20ms / 115VAC at full load INPUT VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC Derating may be needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.93 / 230VAC 0.96 / 115VAC at full load EFFICIENCY (Typ.) 89% 91% 90.50% AC CURRENT (Typ.) 1.4A / 115VAC 0.7A / 230VAC INRUSH CURRENT (Typ.) 35A / 115VAC 70A / 230VAC LEAKAGE CURRENT 1 mA / 240VAC PROTECTION OVERLOAD Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage 150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down overvoltage after 3 seconds OVERVOLTAGE 14 ~ 17V 29 ~ 33V 56 ~ 65V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 95C 5C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, re-power automatically after temperature goes down DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A 30VDC / 1A 30VAC / 0.5A RESISTIVE LOAD ENVIRONMENT WORKING TEMP. -25 ~ +70C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended WORKING HUMIDITY 20 ~ 95% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03% / C (0 ~ 50C) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes SAFETY & EMC MOUNTING Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C 70% RH) EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 EN55024 EN61000-6-2 (EN50082-2) EN61204-3 heavy industry level criteria A, SEMI F47, GL approved The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF 289.9K hrs min. MIL-HDBK-217K (25C) DIMENSION 40x125.2x113.5mm (WxHxD) PACKING 0.67Kg 20pcs / 14.4Kg / 1.16CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 116Mechanical Specification 40 113.5 + +V ADJ. Assignment Assignment 1 FG 1,2 2 AC/N 3 3 AC/L 4 DC OK Relay Contact age. Block Diagram RECTIFIERS EMI FILTER PFC POWER +V I/P & & SWITCHING CIRCUIT -V RECTIFIERS FILTER O.C.P. U.V.P. O.L.P. DETECTION FG CIRCUIT PWM & PFC PFC CONTROL CONTROL O.V.P. Peak Loading 180W 180W 120W 60W Derating Curve Output Derating VS Input Voltage Others 100 150 90 112.5 12V 80 Others 100 70 60 Continuous 75 12V 50 60 40 -250 10 20 30 40 50 55 60 70 (VERTICAL) 88 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 117 125.2 TB2 TB1 1 1 2 3 2 4 3