Features: PSC-96 Series Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 E361935 E205412 True DC OK signal output All wiring 105C long life electrolytic capacitors High operation temperature up to 70C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed OUTPUT Cat. No. PSC-9612* PSC-9615* PSC-9624 PSC-9648 DC VOLTAGE 12V 15V 24V 48V RATED CURRENT 7.5A 6.4A 4A 2A CURRENT RANGE 0 ~ 7.5A 0 ~ 6.4A 0 ~ 4A 0 ~ 2A RATED POWER 90W 96W 96W 96W RIPPLE & NOISE (max) 180mVp-p 180mVp-p 180mVp-p 250mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V VOLTAGE TOLERANCE 1.0% 1.0% 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 2.0% 2.0% 2.0% 2.0% SETUP, RISE TIME < 800ms, < 40ms / 230VAC at full load HOLD UP TIME (Typ.) > 32ms / 230VAC >16ms / 115VAC at full load INPUT VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47Hz~63Hz POWER FACTOR (Typ.) < 0.92 / 230VAC < 0.98 / 115VAC at full load EFFICIENCY (Typ.) 87% 87% 88% 87% AC CURRENT (Typ.) 1.1 A / 115VAC 0.55A / 230VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC 60A / 230VAC PROTECTION LEAKAGE CURRENT <1mA / 230VAC OVER LOAD PROTECTION > 102% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION 90C 10C (RTH2) detect on heat sink of power transistor ENVIRONMENT Protection type: Shut down overvoltage, re-power on to recover WORKING TEMP. -20 ~ +70C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP. / HUMIDITY -40 ~ +85C 10 ~ 95% RH TEMP. COEFFICIENT 0.03% / C (0 ~ 50C) SAFETY & EMC VIBRATION 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant WITHSTAND VOLTAGE I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EMI CONDUCTION & RADIATION EN55022:2006 Class B HARMONIC CURRENT EN61000-3-2:2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EMS IMMUNITY EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OUTPUT that it still meets EMC directives. DC OK Signal Relay contact (24VDC / 1A, 120VAC / 1A) MTBF 120.4K Hrs MIL-HDBK-217F DIMENSION 55x90x99 mm (WxHxD) PACKING 0.4Kg/24 pcs. / 10.8Kg CONNECTION l/P 3 poles, 0/P: 6 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. *Not included in UL E361935 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 18PSC-96 Series Mechanical Specification Unit : mm / inch 55 99 Terminal Pin. No Assign. (TB1) Pin No. Assignment 1 FG 2 AC/N 3 AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V 3,4 DC OUTPUT -V 5,6 DC OK RELAY CONTACT Block Diagram DDCC OO KK EEMMII FFIILLTTEERR RREECCTTIIFFIIEERRSS ++VV PPFFCC PPOOWWEERR II//PP && && CCIIRRCCUUIITT SSWWIITTCCHHIINNGG --VV FFIILLTTEERR RREECCTTIIFFIIEERRSS OO..CC..PP.. DDCC OOKK OO..LL..PP.. OO..VV..PP.. OO..LL..PP.. DDEETTEECCTTIIOONN CCIIRRCCUUIITT PPWWMM&&PPFFCC CCOONNTTRROOLL OO..VV..PP.. OO..TT..PP.. DC OK Relay Contact When the output voltage reaches the adjusted output voltage Contact Close Contact Open When the output voltage drop below 90% rated output voltage Contact Ratings (max.) 30V / 1A resistive load Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=25C 100 100 90 80 80 60 70 60 40 50 20 40 -20 0 10 20 30 40 50 60 70 85 100 110 120 264VAC Ambient Temperature (C) Input Voltage(VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 19 Load (%) 90 Load (%)