Features: PS-S100 Series Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage / Specifications Over temperature ZCS/ZVS technology to reduce power dissipation Cooling by free air convection DIN rail mountable DC OK relay contact No load power consumption < 1W LED indicator for power on 100% full load burn-in test 3 year warranty Cat. No. PS-S10012 PS-S10024 PS-S10048 OUTPUT DC VOLTAGE 12V 24V 48V RATED CURRENT 7.5A 4A 2A CURRENT RANGE 0 ~ 7.5A 0 ~ 4A 0 ~ 2A RATED POWER 90W 96W 96W RIPPLE & NOISE (max) 120mVp-p 150mVp-p 200mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. VOLTAGE ADJ. RANGE 12 ~ 15V 24 ~ 30V 48 ~ 56V VOLTAGE TOLERANCE 1.0% 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% SETUP, RISE TIME 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. HOLD UP TIME (Typ.) 50ms/230VAC 20ms/115VAC at full load INPUT VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC Derating maybe needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE 47~63Hz POWER FACTOR (Typ.) PF 0.95/230VAC PF 0.98/115VAC at full load EFFICIENCY (Typ.) 85% 86% 88% AC CURRENT (max) 1.3A/115VAC 0.8A/230VAC INRUSH CURRENT (Typ.) COLD START: 30A/115VAC 60A/230VAC LEAKAGE CURRENT 1mA/ 240VAC PROTECTION OVERLOAD 105% ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 90C 10C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover SHORT CIRCUIT PROTECTION Power supply shut down at 70C constant current limiting / output voltage goes to 0 re-power on to recover DC OK AKTIV SIGNAL (max.) Relay contact rating (max.): 30V/1A resistive ENVIRONMENT WORKING TEMP. -10 ~ +60C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03% C (0 ~ 50C) VIBRATION Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY & EMC MOUNTING Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25C/70% RH EMI CONDUCTION & RADIATION Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 EN55024 ENV50204 EN61000-6-2 EN61204-3 light industry level criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF 346K hrs min. MIL-HDBK-217K (25C) DIMENSION 55x90x100mm (WxHxD) PACKING 0.42Kg 30pcs / 13.6Kg / 0.82CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 70Mechanical Specification Terminal Pin. No Assign. (TB1) Pin No. Assignment 1 FG 2 AC/N 3 AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V 3,4 DC OUTPUT -V 5,6 DC OK RELAY CONTACT Block Diagram DC OK Relay Contact Derating Curve Output Derating VS Input Voltage Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 71