PS-S40 Series Features: Universal AC input/full range Specifications Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable LED indicator for power on DC OK relay contact No load power consumption < 0.75W 100% full load burn-in test 3 year warranty Cat. No. PS-S4005 PS-S4012 PS-S4024 PS-S4048 OUTPUT DC VOLTAGE 5V 12V 24V 48V RATED CURRENT 6A 3.33A 1.7A 0.83A CURRENT RANGE 0~6A 0~3.33A 0~1.7A 0~0.83A RATED POWER 30W 40W 40.8W 39.8W RIPPLE & NOISE (max) 80mVp-p 120mVp-p 150mVp-p 200mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor VOLTAGE ADJ. RANGE 5 ~ 6V 12 ~ 15V 24 ~ 30V 48 ~ 56V VOLTAGE TOLERANCE 2.0% 1.0% 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. HOLD UP TIME (Typ.) 50ms/230VAC 20ms/115VAC at full load INPUT VOLTAGE RANGE 85~264VAC 120~370VDC FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 78% 86% 88% 88% AC CURRENT (max) 1.1A/115VAC 0.7A/230VAC INRUSH CURRENT (Typ.) COLD START: 30A/115VAC 60A/230VAC LEAKAGE CURRENT 1mA/ 240VAC PROTECTION OVERLOAD PROTECTION 105% ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE PROTECTION 6.25~7.25V 15.6~18V 31.2~36V 57.6~64.8V Protection type: Shut down overvoltage, re-power on to recover OVER TEMPERATURE PROTECTION Power supply shut down at 70C constant current limiting / output voltage goes to 0 re-power on to recover DC OK AKTIV SIGNAL (max.) Relay contact rating (max.): 30V/ 1A resistive ENVIRONMENT WORKING TEMP. -20 ~ +70C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03% C (0 ~ 50C) VIBRATION Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes MOUNTING Compliance to IEC60068-2-6 SAFETY & EMC SAFETY STANDARDS UL508 EN60950-1 compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C 70% RH) EMI CONDUCTION & RADIATION Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 EN55024 ENV50204 EN61000-6-2 EN61204-3 light industry level criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF 301.7K hrs min. MIL-HDBK-217K (25C) DIMENSION 40x90x100mm (WxHxD) PACKING 0.3Kg 42pcs / 13.6 Kg / 0.82CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 66Mechanical Specification 40 100 5 5 5 5 5 Terminal Pin. No Assign. (TB1) +V +V -V -V Pin No. Assignment 1 FG 2 AC/N 3 AC/L + +V ADJ Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V 3,4 DC OUTPUT -V 5,6 DC OK RELAY CONTACT NL 7.5 7.5 Block Diagram RECTIFIERS POWER RECTIFIERS +V EMI I/P & SWITCH- & FILTER -V FILTER ING FILTER O.C.P. DETECTION CIRCUIT CONTROL O.L.P. O.V.P. DC OK Relay Contact age. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 60 40 50 20 40 -20 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 67 90