148 148 42.2 102 505 Option Plug cord Model: 489-1635-L10, 489-1635-L21 AC Fan Model Power cord length (mm) L10 1,000 L 2,100 21 L 120 9AD type Pre-soldered Features 4 10 Low Power Consumption 20 4 17 Power consumption is reduced by approximately 72% * compared with our conventional AC fan. Resin filter kits Long Life Model: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) The San Ace 120AD has an expected life of 60,000 hours (approximately 6 years), approximately 2.4 times that of our * conventional AC fan. 124 1 10.5 0.5 4-4.3 0.3 104.8 0.3 Wide Range A rated voltage range of 100 to 240 VAC allows for usage in both 100 VAC and 200 VAC systems. Rotation speed remains constant even at different input voltages. * Our conventional AC fan is 120 x 120 x 38 mm San Ace 120 , Model No. 109S072UL at a frequency of 60 Hz. (Ribless model depicted) 4-11 0.5 4-2 0.5 Finger guards Color Color 120120 38mm Model: 109-019C Surface treatment: Nickel-chrome plating (silver) Model: 109-019E Surface treatment: Nickel-chrome plating (silver) : 109-019H : Cation electropainting (black) : 109-019K : Cation electropainting (black) Specications Outlet side Inlet side, Outlet side The model no. below has ribs and no sensors. For models without ribs, append1 to the model no. 1 1 1.6 5 5 0 0 1.6 Operating Operating (Note) 1.6 Rated Voltage Frequency Rated Current Rated Input Rated Speed Max. Air Flow Max. Static Pressure SPL Expected Life Voltage Range Temperature 1.6 Model No. -1 3 V Hz A W min m /min CFM Pa inchH2O dB(A) h V 9AD1201H12 100 to 240 90 to 264 50/60 0.08 4.4 3,250 3.0 106 84 0.34 42 20 to 75 60,000 Note: 50/60 Hz compatible. Available options: Low Speed Sensor Please contact us for details on the following specications: Pulse Sensor Lock Sensor 1.5 Common Specications 152.5 0.5 Material Frame: Plastics (Flammability: UL94V-0), Impeller: Plastics (Flammability: UL94V-1) Expected Life Refer to specications Wiring harness for sensor (L10: Survival rate: 90% at 60 , rated voltage, and continuously run in a free air state) Model: 489-1636 Burnout protection at locked rotor condition Motor Protection System 100020 50/60 Hz, 1,500 VAC, 1 minute Dielectric Strength (between power terminal and frame or between lead conductor and frame) 101 Pre-soldered Expressed as the value at 1 m from air inlet side Sound Pressure Level (SPL) Refer to specications (Non-condensing) Operating Temperature 30 to 75 (Non-condensing) Storage Temperature Approx. 290 g Mass Notice The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020 120 9AD type 12012038mm Air Flow - Static Pressure Characteristics Wiring Diagram Dimensions (unit : mm) (With ribs) (inch H2O) (Pa) Standard Standard 0.4 4-4.30.3 90 Mounting Hole 80 0.3 70 FAN 100 to 240 V 50/60 Hz 60 0.2 50 40 with Sensor 30 0.1 20 FAN 10 mA MAX. 10 Yellow Photo Coupler Pull-up resistor +4 to 27.6 V DC 0 3 (m /min) 0 1 2 3 4 Senser output 50 100 150 (CFM) 0 Black 60.5 60.5 GND (0 V) Air ow 104.80.3 380.5 1200.8 Rotating Direction Air Flow Direction Specications for Low-speed Sensors with Sensor Connector: Tyco Electronics AMP 171822-2 (Pin1 Sensor output: YellowPin2 : Black) Typical standard model: 9AD1201H1H Contact: Tyco Electronics AMP 170262-1 Lead Wire Output circuit: Open collector Sensor scheme AWG24 VCE27.6 V DC MAX. 4-4.30.3 UL1007 Ic10 mA MAX.VCE (SAT) 1.0 V MAX. Example 1: when steady running Mounting Hole Inside of DC fan Fan power Pull-up voltage 4 to 27.6 V DC Trip point Fan speed Pull-up resistor Photocoupler Sensor output * Recommended connectors and contacts are listed below. Ic10 mA MAX. Sensor (VCE) Startup delay Detection delay Connector: Tyco Electronics AMP 172211-2 Contact: Tyco Electronics AMP 170376-1 Sensor output H H L VCE (SAT) 60.5 60.5 104.80.3 380.5 1200.8 Example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. Rotating Direction Air Flow Direction Fan power Reference Dimension of Mounting Holes and Vent Opening (unit : mm) Trip point Inlet Side Outlet Side Fan speed 104.80.3 104.80.3 4-4.5 4-4.5 Startup delay Detection delay Sensor output H H L Startup delay: 183 sec. Detection delay: 3 sec. MAX. -1 Trip point: 1700 min 118 118 127 135 Static pressure AC Power supply AC Power supply 118 1200.8 1200.8 104.80.3 104.80.3 10010 104.80.3 118 104.80.3