E S A E High Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 250 Watt, 120 Volt Standard Flow SEE DETAIL OR PRESSURE TAP OPTION 3.74 MOTOR COOLING 1.25 95.0 DISCHARGE 31.8 DISCHARGE INCH MM 2.37 INLET 60.2 3X 90 5.90 1.25 150.0 31.8 .17 MAX. 4X HOLES THRU, 4.3 LOCATED AS SHOWN ON 37 6.50 BOLT CIRCLE 165.10 C L SPEED CONTROL/ EARTH GROUND 1.3 CALIBRATION 1.04 .17 MAX75 HOLE THRU, 33.0 26.4 4.3 19.1 33 LOCATED AS SHOWN ON MOTOR COOLING ACCESS TO SPEED CONTROL/ 45 6.40 INLET BOLT CIRCLE CALIBRATION 162.6 AC INPUT NEUTRAL AC INPUT NEUTRAL VOLTAGE VOLTAGE LINE LINE 108V-132V 108V-132V PIN NOT USED PIN NOT USED ISOLATED SPEED HIGH CONTROL 0-10V DC LOW INPUT REQUIRED DETAIL DETAIL (ELECTRICAL) (MECHANICAL) POWER/CONTROL CONNECTION DETAILS Part/ Model Number Specification Units 116634 116640 116633 116639 116632 116638 Stages - 1 1 2 2 3 3 in. H2O 29.5 29.5 40.1 40.1 78.4 78.4 Max Sealed Vacuum mbar 73.5 73.5 99.9 99.9 195.3 195.3 in. H2O 30.4 30.4 41.3 41.3 80.5 80.5 Max Sealed Pressure mbar 75.7 75.7 102.9 102.9 200.5 200.5 CFM 75.9 75.9 65.6 65.6 56.4 56.4 Max Flow Rate m3/hr 129 129 111.5 111.5 95.9 95.9 Inches 0.33 0.33 1.25 1.25 2.14 2.14 Length (I) mm 8.4 8.4 31.8 31.8 54.4 54.4 Inches 5.08 5.08 6.35 6.35 6.89 6.89 Length (L) mm 129 129 161.3 161.3 175 175 Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical Notes: Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase. Input Current: 5 amps AC RMS Operating Temperature (Ambient Air and Working Air): 0 C to 50 C Storage Temperature: -40 C to 85 C Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum. Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower housing. Approximate Weight: 6 Lbs. / 2.2 Kg. Regulatory Agency Certi cation: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2 113 under File LR 43448. Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6 w/SL-156 contacts (suppied by customer) mates with post header assembly. Mating harness available upon request. TM Optional IntelliGen controller available for customized performance and features including: tachometer output card Universal AC input (100V-240V). This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 7 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com R C N I High Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 250 Watt, 120 Volt Standard Flow Typical Performance 3 Flow (m /hr) 116634, 116640 116633, 116639 116632, 116638 Flow (CFM) 3 Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92 Hg, Sea Level, 68 F) Vacuum performance available upon request. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 8 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com Speed (RPM) Current (A) Pressure (inch H O) Power Demand 2 (Watts) Pressure (mbar)