E S A E High Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 1200 Watt, 240 Volt Standard Flow - IntelliGen (TM) PRESSURE TAP DISCHARGE OPTION 3.74 95.0 1.25 31.8 INCH 2.37 MM INLET 60.2 3X 90 1.25 5.90 31.8 150.0 2.60 MAX. MAX17 66.0 4X HOLES THRU, 4.3 MOTOR COOLING 2.40 LOCATED AS SHOWN ON INLET 61.0 1 2 6.50 3 BOLT CIRCLE 4 165.10 5 C L SPEED CONTROL/ CALIBRATION MOTOR COOLING 1.04 .75 33 19.1 DISCHARGE 26.4 26 49 45 SEE DETAIL & 2.12 EARTH GROUND .17 53.8 HOLE THRU, 4.3 6.87 LOCATED AS SHOWN ON 174.5 6.40 BOLT CIRCLE 162.6 ISOLATED SPEED LOW NOT USED CONTROL 0-10V. D.C. 1 HIGH 1 NOT USED INPUT REQUIRED 2 2 GROUND GROUND 3 3 AC INPUT VOLTAGE AC INPUT VOLTAGE 208V-264V 208V-264V 4 4 ACCESS TO SPEED CONTROL/ 5 5 CALIBRATION DETAIL DETAIL (ELECTRICAL) (MECHANICAL) POWER/CONTROL CONNECTION DETAILS Part/ Model Number Specification Units 117416 117415 Stages - 3 3 in. H2O 154 154 Max Sealed Vacuum mbar 383.6 383.6 in. H2O 169 169 Max Sealed Pressure mbar 421 421 CFM 87 87 Max Flow Rate m3/hr 147.9 147.9 Speed Control - Mechanical Electrical Notes: Input Voltage Range: 208-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS. Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above. Operating Temperature (Ambient Air and Working Air): 0 C to 50 C Storage Temperature: -40 C to 85 C (Internal electronic controller is thermally protected). Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum. Isolated Speed Control: Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum. Note: Setting of onboard potentiometer can eect control voltage range and maximum speed can be attained before reaching 10 VDC Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise). Speed Control Drift with Temperature: Analog Mode: Typ. +-4% from nominal speed at +23 C. Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C. Approximate Weight: 6 Lbs. / 2.2 Kg. Regulatory Agency Certi cation: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2 113 under File LR 43448. Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with male pins on 16 awg lead wire (suppied by customer) mates with post header assembly. Mating harness available upon request. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 19 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com R C N IHigh Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 1200 Watt, 240 Volt Standard Flow - IntelliGen (TM) Typical Performance 3 Flow (m /hr) 117416, 117415 Flow (CFM) 3 Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92 Hg, Sea Level, 68 F) Vacuum performance available upon request. INSTALLATION: The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration. Connections: All of the Windjammer IntelliGen series blowers have a standard 5 pin connector. A mating connector with leads is supplied with single pack units only. Negative pressure applications will exhibit reduced performance. Exhaust air must be prohibited from being recycled to inlet air. If blower is to be cycled frequently, the DC speed command should be used. For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters. Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement. Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry. Utilizes AMETEKs IntelliGen control electronics. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 20 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com Current (A) Speed (RPM) Pressure (inch H O) Power Demand 2 (Watts) Pressure (mbar)