C L High Voltage Brushless DC Blowers 5.7 (145mm) BLDC Thru Flow Blower 400 Watt, 240 Volt Standard Flow ISOLATED SPEED LOW NOT USED CONTROL 0-10V. D.C. 1 HIGH 1 NOT USED INPUT REQUIRED 2 2 GROUND GROUND 3 3 AC INPUT VOLTAGE AC INPUT VOLTAGE INCH 216V-264V 216V-264V 4 4 MM 5 5 DETAIL DETAIL (ELECTRICAL) (MECHANICAL) POWER/CONTROL CONNECTION DETAILS PRESSURE TAP OPTION 1.04 3.74 26.4 95.0 DISCHARGE 1.25 31.8 2.37 60.2 INLET 3X 90 5.90 .48 1.25 150.0 3X 12.2 31.8 MAX. 39 SPEED CONTROL/ .17 4X HOLES THRU, CALIBRATION 4.3 LOCATED AS SHOWN ON 6.50 43 ACCESS TO SPEED CONTROL/ BOLT CIRCLE 165.10 CALIBRATION 1.25 .23 31.8 3X HOLES .75 33 5.8 19.1 .37 DEEP MINIMUM 45 9.4 EARTH GROUND EQUALLY SPACED AS SHOWN ON .17 4.00 A BOLT CIRCLE HOLE THRU, 4.3 101.6 LOCATED AS SHOWN ON 6.40 BOLT CIRCLE 162.6 SEE DETAIL OR Part/ Model Number Specification Units 117629 117630 Stages - 1 2 in. H2O 28 47 Max Sealed Vacuum mbar 69.7 117.1 in. H2O 31 50 Max Sealed Pressure mbar 77.2 124.6 CFM 67 65 Max Airflow m3/hr 113.9 110.5 Inches .69 1.6 Length (I) mm 17.5 40.6 Inches 3.21 4.12 Length (L) mm 81.5 104.6 Speed Control - Electrical Electrical Notes: Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase. Input Current: 5 amps AC RMS Operating Temperature (Ambient Air and Working Air): 0 C to 50 C Storage Temperature: -40 C to 85 C Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum. Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower housing. Approximate Weight: 6 Lbs. / 2.2 Kg. Regulatory Agency Certi cation: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2 113 under File LR 43448. Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with sockets for 18 awg lead wire (suppied by customer) mates with post header assembly. Mating harness available upon request. TM Optional IntelliGen controller available for customized performance and features including tachometer output card Universal AC input (100V-240V). This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 9 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.comHigh Voltage Brushless DC Blowers 5.7 (145mm) BLDC Thru Flow Blower 400 Watt, 240 Volt Standard Flow Typical Performance 3 Flow (m /hr) 117629 117630 Flow (CFM) 3 Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92 Hg, Sea Level, 68 F) Vacuum performance available upon request. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 10 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com Speed (RPM) Current (A) Pressure (inch H O) Power Demand 2 (Watts) Pressure (mbar)