E S A E High Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 400 Watt, 240 Volt Standard Flow PRESSURE TAP 43 DISCHARGE OPTION 3.74 MOTOR COOLING 95.0 DISCHARGE 1.25 31.8 37 INCH SEE DETAIL MM & 2.37 INLET 60.2 C L 3X 90 SPEED CONTROL/ 1.25 CALIBRATION 5.90 31.8 150.0 MAX17 4X HOLES THRU, 4.3 2.38 LOCATED AS SHOWN ON 60.5 6.50 BOLT CIRCLE 165.10 1.3 MAX. 33.0 1.04 .75 33 MOTOR COOLING 26.4 19.1 INLET 45 ACCESS TO SPEED CONTROL/ CALIBRATION EARTH GROUND .17 HOLE THRU, 4.3 LOCATED AS SHOWN ON 6.40 BOLT CIRCLE 162.6 5 4 3 2 1 5 4 3 2 1 ISOLATED SPEED LOW NOT USED CONTROL 0-10V. D.C. HIGH NOT USED INPUT REQUIRED GROUND GROUND AC INPUT VOLTAGE AC INPUT VOLTAGE 216V-264V 216V-264V DETAIL DETAIL (ELECTRICAL) (MECHANICAL) POWER/CONTROL CONNECTION DETAILS Part/ Model Number Specification Units 117634 117640 117633 117639 117632 117638 Stages - 1 1 2 2 3 3 in. H2O 28 28 45 45 60 60 Max Sealed Vacuum mbar 69.7 69.7 112.1 112.1 149.5 149.5 in. H2O 30 30 51 51 72 72 Max Sealed Pressure mbar 74.7 74.7 127 127 179.4 179.4 CFM 70 70 67 67 65 65 Max Flow Rate m3/hr 119 119 113.9 113.9 110.5 110.5 Inches 2.53 2.53 1.25 1.25 2.14 2.14 Length (I) mm 64.3 64.3 31.8 31.8 54.4 54.4 Inches 5.08 5.08 5.99 5.99 6.89 6.89 Length (L) mm 129 129 152.1 152.1 175 175 Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical Notes: Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase. Input Current: 5 amps AC RMS Operating Temperature (Ambient Air and Working Air): 0 C to 50 C Storage Temperature: -40 C to 85 C Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum. Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower housing. Approximate Weight: 6 Lbs. / 2.2 Kg. Regulatory Agency Certi cation: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2 113 under File LR 43448. Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with sockets for 18 awg lead wire (suppied by customer) mates with post header assembly. Mating harness available upon request. TM Optional IntelliGen controller available for customized performance and features including tachometer output card Universal AC input (100V-240V). This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 11 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com R C N IHigh Voltage Brushless DC Blowers 5.7 (145mm) BLDC Bypass Blower 400 Watt, 240 Volt Standard Flow Typical Performance 3 Flow (m /hr) 117634, 117640 117633, 117639 117632, 117638 Flow (CFM) 3 Data presented represents blower performance at STANDARD AIR DENSITY, WHICH IS: .075 lb./ft (29.92 Hg, Vacuum performance available upon request. Sea Level, 68 F). This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department. AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B 12 627 Lake Street, Kent OH 44240 PRECISION MOTION CONTROL USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258 www.ametektip.com Speed (RPM) Current (A) Pressure (inch H O) Power Demand 2 (Watts) Pressure (mbar)