Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com Solving your relay requirements since 1922 Hermetically sealed G Series TDR Delay on Make or Delay on Break timing modes Thermal device 3 AMP rating 1 - 115V input voltage range - works on AC or DC Isolated output contacts Fixed delay times only Initial and reset (release) delay device Long life UL File E96739 (M) Timing Mode: Timing cycle begins upon application of power to the heater terminals. At the end of the initial delay time the relay contacts transfer and remain in a transferred state until input power is removed. When the heater input power is removed, the contacts transfer back to their original state at the end of a reset (release) delay period. Timing Diagram: Contact Information: Arrangement: 1 form A (SPST - Normally open) - Delay on Make 1 form B (SPST - Normally closed) - Delay on Break Contact Material: Silver - Cadmium Oxide Rating (Resistive): 3A 115V AC Expected Life 25C: 500,000 operations minimum at rated loads Environmental Information: Temperature Range: Operating & storage: -55C to +80C, (-67F to +176F) Mechanical Information: Termination & Enclosure: Octal style, or 9-pin miniature style glass envelope. See Diagram A & B. Weight: 1 oz. (28g) Outline Dimensions: Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com Solving your relay requirements since 1922 Timing Specifications: Timing - Fixed: 1 through 300 secs. - (octal style) or 1 - 120 secs. (9-pin miniature style) Timing Tolerance: 20% - Tighter tolerances are available. Repeatability: 5% Release Time: Contact factory Timing Cycle Interrupt Transfer: none Initial Dielectric Strength: 1-10 Second Type: Between open contacts: 250V RMS Between contacts & coil: 500V RMS 15 - 300 Second Type: Between open contacts: 800V RMS Between contacts & coil: 500V RMS Input Information: Voltage: AC or DC - 6V, 12V, 26V, 50V and 115V. Other voltages are available. Power Requirement: 2.0 Watts approx. Transient Protection: impervious to transients Polarity Protection: None required Input Voltages & Limits: Nominal Minimum Maximum 6V AC/DC 4V 8V 12V AC/DC 10V 14V 26V AC/DC 22V 30V 50V AC/DC 42 58V