SGX Europe Sp. Z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland SGX-7H2S-100 Datasheet OUTLINE Industrial Hydrogen Sulphide (H2S) Sensor All dimensions are in mm All tolerances are 0.15mm PERFORMANCE Output signal 1700 400 nA / ppm Typical Baseline Range 0.5 ppm H S equivalent 2 (pure air) T90 Response Time < 60 seconds Measurement Range 0 - 100 ppm Maximum Overload 500 ppm Linearity Linear Repeatability < 1% H S equivalent 2 Recommended Load 10 ohms Resistor Resolution (Electronics <0.1 ppm typical dependent) OPERATING CONDITIONS Temperature Range -40C to +50C Pressure Range 800 to 1200 mbar Operating Humidity 15% to 90% RH Range LIFETIME Long Term Output Drift < 20% per annum Recommended Storage 0C to 20C Temp Expected Operating Life > 24 months in air SGX Sensortech 2012-2020 DS-0325 SGX-7H2S-100, Issue 1, 26-Mar-2020, Page 1/3 SGX Europe Sp. Z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland CROSS SENSITIVITY DATA GAS CONCENTRATION SGX-7H2S-100 Carbon Monoxide 300ppm < 3ppm Sulphur Dioxide 5ppm <1ppm Nitrogen Dioxide 5ppm <0.5ppm Nitric Oxide 50ppm <1ppm Hydrogen 500ppm <1ppm Chlorine 1ppm 0ppm Ethylene 100ppm 0ppm Carbon Dioxide 5000ppm 0ppm * See Important Notes Output vs Temp SGX Sensortech 2012-2020 DS-0325 SGX-7H2S-100, Issue 1, 26-Mar-2020, Page 2/3