Telaire Accessories Calibration Kits, Enclosures, Software, Cables Calibration Kits 2080 CO View Logging Software 2 The Calibration Kit Model T2075NG includes all of the CO2 View is a Windows based program that interfaces necessary components for calibrating the Telaire 7001 with the 7000 series. This easy to use program displays and Ventotstat 8000 and 8100 series models. The kit is and graphs real-time CO levels at a user adjustable 2 housed in a carrying case with only one replacement interval. part (calibration gas (not supplied)) required. A 16 liter gas bottle (not supplied) can perform up to 20 UIP T2090 calibrations. Calibration Kit Model T2076NG calibrates Modify your 8000 series (T8100, T8200, T8300). the Vaporstat 9002. 7001 Accessories Accessory Enclosures The Telaire 7001 hand held CO and temperature 2 Telaire offers four enclosures to expand the Ventostat monitor is equipped with an output for recording data. and Vaporstat installation options: Model T1508 The cable, Model T2070, can be used with devices that Aspiration Box, Model T1505 Splash Resistant accept a 0 to 4V signal. Enclosure, and Model T1551 and T1552 Outdoor Air Enclosures. A relative humidity and datalogging kit with graphing software, Model T2077, is available for long term Software monitoring. Windows based VG Graphing Software allows you to easily download your IAQ measurements and Part 62933 is an adapter for international operation. customize graphs. Amphenol Advanced SensorsCalibration Kits T2075NG and T2076NG Calibration Process The calibration is simple and can be done in just a few minutes. Each CO model has a calibration process 2 similar to the following: Connect the tubing assembly to the sensor and connect the regulator to the gas bottle. Initiate the calibration process by using the sensor buttons and display. The process is automatically run by the sensor and will signal upon completion. Last, disconnect the tubing and gas regulator. The illustration shows the complete set-up for calibrating a sensor with display. T2075NG Components *Nitrogen gas not included. Requires disposable gas tank: CGA600, 99.95% The Calibration Kit Model T2075NG includes: Nitrogen 20 bar fill pressure, approximately one liter. Instruction sheet T2076NG Components Tubing assembly Gas regulator with gauge The Calibration Kit Model T2076NG includes: Instruction sheet Carrying case. Tubing assembly Gas regulator with gauge Calibrates the following models: Carrying case. Ventostat 8000 and 8100 Series Flow Meter Telaire 7000 Series Use in conjunction with UIP software for T8000 series Calibrates the following models: (T8100, T8200, T8300) Vaporstat 9002 *Nitrogen gas not included. Requires disposable gas tank: CGA600, 99.95% Nitrogen 20 bar fill pressure, approximately one liter.