www.Amprobe.com ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter Test Voltage and Amperage Simultaneously The ACD-14-PRO offers a complete range of measuring The Amp-Tip function allows for precise measurement of functions for both HVAC and electrical applications. This current down to the tenth of an amp for reliable, accurate modern clamp meter features a large backlit LCD dual current measurement of both large and small diameter display and is capable of simultaneously displaying voltage wires. The low pass filter allows measurement of current and amps. The ACD-14-PRO is packed with features and voltage on variable frequency drives (motors with speed including TRMS, low pass filter, in-rush current, frequency, controlled by frequency). The meter features a rubber over- resistance, capacitance, temperature, DC micro-amps, mold enclosure that provides extra durability and is safety Amp-Tip and non-contact voltage detection. rated to CAT III 600 V. Non-Contact Voltage Detection (NCV) ACD-14-PRO Amp-Tip function for precise Low Current Measurement Features Large LCD with dual display that can display voltage and amps concurrently True-RMS for accurate voltage measurements in noisy environments Low pass filter for current and voltage measurements on variable frequency drives Rotary Switch for Amp-Tip function for precise low one-hand operation current measurement down to 0.1 amp HVAC applications with temperature, Large LCD Dual Display TRMS Function DC micro-amps and capacitance with Backlight provides accurate measurements In-rush current Upper Display: Temperature Reading for AC current Non-contact voltage detection (NCV) Lower Display: Reading for V, Hz, , F Audible continuity and diode test and A and Temperature Data hold Rubber Data Hold Button Overmold Auto ranging for extra durability Auto power off Built-in low pass filter Low battery indicator Safety rated CAT III 600 V Input Terminals ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter Amprobe info amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2015 Amprobe For detailed specifications and ordering go to www.Amprobe.com 6006537 Awww.Amprobe.com ACD-14-PRO Key Applications The Amprobe ACD-14-PRO features low profile jaws to test The Amprobe ACD-14-PRO can test and display voltage and current measurements simultaneously with the large in tight spaces with TRMS for accurate measurements. backlit LCD dual display, for voltage drop tests and other applications. Voltage drop test - dual display allows user to view Testing variable frequency drives with low pass filter. voltage and current simultaneously to assess voltage drop for Variable frequency drives are energy efficient motors where current changing from zero to a maximum value. speed is controlled by frequency. These motor drives generate high frequency noise, which may cause standard meters to Voltage drop test is required by National Electrical Code (NEC) to provide erroneous readings when measuring voltage and current. ensure normal operation and efficiency. It defines the maximum The low pass filter will remove this noise and provide accurate percentage of the voltage drop between maximum voltage measurements. at zero current and minimum voltage at maximum current. This assures that electrical equipment and motors are working Capacitance measurement for start and run motor capacitors. within specified voltage to avoid potential damage to electrical Resistance and continuity functions to verify quality of components. electrical connections and to check if motor and transformer coils are working properly. Functions for core HVAC applications: Temperature In-rush current measurement to verify maximum current measurement (with included thermocouple), capacitance for surge during motor start-up. Too high of in-rush current can cause start-up and run capacitors, and DC micro-amps for flame sensors gradual damage of components and may cause fuses or circuit testing. breakers to trip. Accurate measurement of current, voltage and DC micro-amps output for measurement of flame sensors. frequency on all electrical systems including distorted, non- Test the proper operation of the flame sensor safety system in gas sinusoidal signals (True-RMS function). appliances. A broken sensor in a gas appliance will prevent the Amp-Tip is a small wire guide that is built into the tip of the main safety valve from opening and the appliance will not work. clamp meter jaws. It allows for precise measurement of low-current down to the tenth of an amp on small diameter wires, to provide reliable, accurate measurements. All Amprobe tools, including the Amprobe ACD-14-PRO, are rigorously tested for safety, accuracy, reliability, and ruggedness in our state-of-the-art test lab. In addition, Amprobe products that measure electricity are listed by a 3rd party safety lab, either UL or CSA. This system assures that Amprobe products meet or exceed safety regulations and will perform in a tough, professional environment for many years to come. Amprobe info amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2015 Amprobe For detailed specifications and ordering go to www.Amprobe.com 6006537 A