Data Sheet ACDC-100 TRMS 1000A AC/DC Clamp-On Multimeter Where accuracy, quality, and the newest technology meet. The ACDC- 100 offers superior AC/DC measurement capabilities, highest product quality and enhanced ergonomics design. The TRMS version addresses needs of professionals who rely on performance and reliability. True RMS Backlight Capacitance test AC/DC voltage to 600V Resistance Continuuity Beeper Relative zero mode Auto power off Data hold MAX capture function for in rush current measurements (30 mS response) No hassle Large, easy to read warranty digital display No waiting. Diode Test No shipping Audible continuity charges. Accommodates conductors up to Our commitment to 50mm (2.00) in diameter high-quality products Third hand - test probe holder and customer service Rubber over-molded case with is demonstrated by built-in probes storage our industry exclusive No Hassle warranty. Carrying case, test leads, batteries In the unlikely event (installed) and user manual included that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: 500 MSLP limit) 600V Amprobe Test Tools www.Amprobe.comData Sheet 1000A ACDC-100 TRMS AC/DC Clamp-On Multimeter Electrical Specifications Accuracy is (% reading digits + number of digits) or otherwise specified, at 23 5 & less than 75% R.H. Function Range Accuracy DC Voltage 400.0 mV 0.3% + 3d 4.000V, 40.00V, 400.0V 0.5% + 3d 600V 1.0% + 4d NMRR : >50dB 50/60Hz CMRR : >120dB DC, 50/60Hz, Rs=1k Input Impedance : 10M , 30pF nominal (1000M for 400.0mV range) AC Voltage 50Hz ~ 500Hz 400.0mV 1) 4.0% + 4d 50Hz ~ 60Hz 4.000V, 40.00V, 400.0V 1.0% + 4d 60Hz ~ 500Hz 4.000V, 40.00V, 400.0V 1.5% + 4d 50Hz ~ 500Hz 600V 2.0% + 4d CMRR : >60dB DC to 60Hz, Rs=1k Input Impedance: 10M , 30pF nominal ACDC-100 TRMS Crest Factor: < 1.6 : 1 at full scale & < 3.2 : 1 at half scale 1) Selection by RANGE button manually, and is specified AC 60mV and up Resistance 400.0 0.8% + 6d 4.000k , 40.00k , 400.0k 0.6% + 4d 4.000M 1.0% + 4d 40.00M 2.0% + 4d Open Circuit Voltage : 0.4VDC typical Audible Continuity Tester Open Circuit Voltage: 0.4VDC typical Range: 400.0 Accuracy: 1.5% + 6d Audible threshold: between 10 and 120 . Diode Tester Open Circuit Voltage Test Current (Typical) < 1.6 VDC 0.4mA Capacitance 500.0nF, 5.000F, 50.00F, 1) 2) 3) 500.0F, 3000F 3.5% + 6d 1) Additional 50.00nF range accuracy is not specified 2) Accuracies with film capacitor or better 3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V DC Current (Clamp-on) 1) 2) 400.0A 0.0A ~ 400.0A 1.5% + 4d 1) 2) 1000A 400A ~ 800A 1.5% + 4d 1) 2) 800A ~ 900A 2.0% + 4d 1) 2) 900A ~ 1000A 5.0% + 30d 1) Induced error from adjacent current-carrying conductor: < 0.01A/A 2) Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A. Amprobe Test Tools www.Amprobe.com