Data Sheet CO2-100 CO2 Hand-Held Meter Instant feedback with CO2 levels, with additional temperature and humidity measurement. Built in alarm warns against dangerous CO2 levels. The portable CO2-100 Air Quality meter is designed to measure air quality compliance in occupied spaces such as offices, production floors, schools or hospitals. n Low drift portable meter for checking indoor air quality n CO2 Measurement up to 9999 ppm n Triple display with simultaneous CO2, Temperature and relative humidity readings n Selectable display of Dew Point and Wet Bulb n Air Quality Analysis with displays of: n TWA display (time-weighted average) for 8 hrs period n 15 minutes STEL (short-term exposure limit) value n High performance low drift sensor designed with NDIR No hassle (Non-Dispersive Infrared) waveguide technology warranty n Easy to read large LCD display No waiting. n Manually calibratable No shipping n Audible alarm threshold setting to setup warning against charges. carbon dioxide level Our commitment to n Backlight function for working in dark area high-quality products n Optional PC download capabilities and customer service is demonstrated by n Data Hold our industry exclusive n Maximum, minimum, average functions No Hassle warranty. In the unlikely event n Long time drift compensation for accurate readings that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: 500 MSLP limit) Amprobe Test Tools www.Amprobe.comData Sheet CO2-100 CO2 Hand-Held Meter Specifications Measuring Range CO2 0 ~ 9999 ppm 5001 ~ 9999 ppm (out of scale range) Temp. Range -10C to 60C (14F to 140F) RH Range 0% ~ 95% DP (Dew Point Temp.) -20C to 59.9C (-4F to 139.8F) WB (Wet Bulb Temp.) -5.0C to 59.9C (24.8F to 139.8F) Resolution 1ppm - CO2 concentration, 0.1C / F - Temp, 0.1% RH - Humidity Accuracy 30ppm5% of reading(CO2) (0~5000ppm) others rang accuracy are not specified 0.6C / 0.9F, 3% RH (at25C ,10~90%) others 5% for other RH range Sensing Tech CO2 -NDIR sensor Humidity Rotronic capacitor type Warm-up Time 30 seconds Response Time About 30 seconds Alarm sound level 80 dB Operating condition 0C to 50C (32F to 122F), 0 ~ 95% RH (avoid condensation) for CO2 Storage Condition -20C to 60C (-4F to 140F), 0~99%RH (avoid condensation) Power Supply AA type (UM-3) x 4 pcs Battery Life > 10 hours Standard packing includes Meter, Manual, Batteries and Hard carrying case Dimension 210(L) x 70(W) x 58(H) mm ( 8.3 x 2.8 x 2.3 in) Weight Approx. 182g (0.40 lb) Amprobe Test Tools website: www.Amprobe.com email: info amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 2009 Amprobe Test Tools. All rights reserved. 7/2009 3520585 Rev A Amprobe Test Tools www.Amprobe.com