Data Sheet PRM-4 Phase Sequence and Motor Rotation Tester Identifies 3-phase sequence and open phase check Motor shaft rotation indication protected by CAT III circuitry CAT III 600V rated for both testing segments Meets current EN61010 safety requirements, CSA, EN61557-7 Supplied with three CAT III rated color coded large alligator clips and test leads Zippered carrying case for portability No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products Included Accessories and customer service Test Leads (red, green, and blue) with is demonstrated by alligator clips (TL-PRM-4), Soft Vinyl our industry exclusive Case, Users Manual, 9 V Battery No Hassle warranty. Optional Accessories In the unlikely event TL-PRM-4 Replacement Test Leads that an Amprobe Test FP900 Replacement Fuses Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: 500 MSLP limit) 600V Amprobe Test Tools www.Amprobe.comData Sheet PRM-4 Phase Sequence and Motor Rotation Tester General Specifications Operating Environment 0 C to 40 C at <80 % R.H. Power Single standard 9 V battery NEDA 1604 JIS 006P IEC 6F22 Battery life Approximately 200 hours typical with carbon-zinc battery Low battery indication The BATT LED does not come ON when TEST button is pressed Dimensions (H x W x D) 153 mm x 72 mm x 35 mm (6.02 x 2.83 x 1.37 in) Weight Approximately 218 g (7 oz) including battery. Environment Indoor use Altitude 2000 m (6561 ft.) Overload protection 600 V ac Agency Approvals CE, cCSAus Safety Conforms to EN61010-1:2001 CAT III 600V, Pollution degree 2, Class 2 CSA 22.2 -1010-1 EN61557-7 EMC Conforms to EN61326-1. This product complies with requirements of the following European Commu- nity Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amend- ed by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicin- ity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Electrical Specifications Function Range Phase Sequence Input Voltage 3 phase to phase inputs 100 V ac to 600 V ac max. Frequency 45 to 70 Hz Operating Time 10 minutes ON maximum at 600 V ac 10 minutes OFF minimum at 600 V ac 3-Phase load Approx. 7 mA per phase of ac power source Motor Rotation Operating Time 10 minutes ON maximum 10 minutes OFF minimum. Motor Rotation tester field 14 mA of 9 V battery Amprobe Test Tools Amprobe Test Tools Europe website: www.Amprobe.com In den Engematten 14 email: info amprobe.com 79286 Glottertal, Germany Everett, WA 98203 2008 Amprobe Test Tools. All rights reserved. Tel.: +49 (0) 7684 8009 - 0 Tel: 877-AMPROBE 2/2008 3303533 Rev A Amprobe Test Tools www.Amprobe.com