SECTION 3 SBE 80 / SBO 60 SBE 80 / SBO 60 Connectors - up to 80 Amps SBE and SBO connectors build on the capability of the two pole SB connectors by offering up to 8 auxiliary power / signal contacts along with an IEC 60950 touch safe housing. The center of the main connector features a connector holder for either: two PP15-45, two PPMX, or APPs innovative 1x4 auxiliary connector. Touch Safe Interface Minimizes potential contact with live circuits per IEC 60950 Up to 8 Last Mate / First Break Auxiliarys Enables intelligent power switching, CAN and interlock loop circuitry, as well as power up to 20 amps per pole Silver Plated Wire Contacts up to 4 (25 mm) Allows UL rated currents up to 80 amps per pole SBE 80 / SBO 60 ORDERING INFORMATION SBE 80 / SBO60 Housings Mated Length The smallest size of SBE , X, O style housing. SBE 80 and SBO 60 housings of the same Voltage Color Code can be mated but is not recommended as it invalidates UL 112.2 approvals. SBO 60 housings do not meet EN1175-1 requirements for industrial trucks. 4.42 Description ----- SBE 80 Part Numbers ----- ----- SBO 60 Part Numbers ----- Minimum Quantity .... 400 25 400 25 ...... Yellow SBE80YEL-BK SBE80YEL SBO60YEL-BK SBO60YEL Orange SBE80ORN-BK SBE80ORN SBO60ORN-BK SBO60ORN Side View Red SBE80RED-BK SBE80RED SBO60RED-BK SBO60RED 26.3 Gray SBE80GRA-BK SBE80GRA N/A N/A Top View 1.03 White N/A N/A SBO60WHT-BK SBO60WHT 58.9 46.0 2.32 1.81 69.6 2.74 5.1 0.20 14.6 SBE 80 / SBO 60 Silver Plated Primary Power Wire Contacts 0.58 49.5 Use two silver plated contacts per housing for the best electrical performance and 1.95 durability up to 10,000 mating cycles. See reducing bushings in accessory section for smaller wires. Dimensions Mating - A - - B - AWG mm Force - Loose Piece Part Numbers - inches mm inches mm Minimum Quantity ........... 1,000 100 ................................................... 4 25 Low 1339G4-BK 1339G4 * 0.28 7.11 0.35 9.0 6 16 High 1339G1-BK 1339G1 * 0.22 5.59 0.29 7.3 * Sold as pairs, (2) parts ship for every 1 ordered. 39.4 1.55 13.0 B 0.51 7.6 0.30 A All Data Subject To Change Without Notice - 77 - www.andersonpower.com SBE 80 / SBO 60 CONNECTOR SPECIFICATIONS Mechanical Electrical Wire Size Range AWG mm Current Rating Amperes SBO60 SBE80 Power Contacts 16 to 6 1.3 to 13.3 Primary Power (6 AWG) 70 80 Auxiliary Contacts 24 to 10 0.25 to 5.3 Powerpole Auxiliary (12 AWG) 20 20 1x4 Auxiliary (12 AWG) 20 20 Max. Wire Insulation Diameter in. mm PPMX Auxiliary (20 AWG) 7 UL 5 CSA Power Contacts 0.440 11.200 Powerpole Auxiliary 0.175 4.450 Voltage Rating AC/DC UL 1977 EN1175-1 4 1x4 Auxiliary 0.140 3.600 Primary Power 600 150 4 Powerpole Auxiliary 600 150 Operating Temperature F C 1x4 Auxiliary 200 SBO and SBE Housings -4 to 221 -20 to 105 PPMX Auxiliary 300 Mating Cycles No Load by Plating Silver (Ag) Gold (Au) Dielectric Withstanding Voltage Primary Power Power Contacts 10,000 Volts AC 2,200 Powerpole Auxiliary 10,000 1x4 Auxiliary 10,000 Avg. Mated Contact Resistance Milliohms PPMX Auxiliary 5,000 1 1/4 of 6 AWG wire 0.200 Hot Plug Current Rating Amperes - 250 cycles at 120V DC Avg. Mating / Unmating Force Lbf. N Power 60A Main Connnector Housing 16 70 Powerpole Auxiliary 30A Per Powerpole 5 22 1x4 Auxiliary 5A Per Contact in 1x4 Auxiliary 0.7 3.0 Per PPMX Housing 4.50 20.00 Materials Housing Min. Contact / Spring Retention Force Lbf. N SBO and Powerpole Plastic Resin Polycarbonate Power Standard Housing 50 222 SBE and 1x4 Auxiliary Housing Polycarbonate / PBT blend Powerpole Housing 25 111 Contact Retention Spring Stainless Steel 1x4 Auxiliary Housing 10 44.5 PPMX Housing 12 53 Housing Flammability Rating UL94 V-0 Protection Power & Powerpole Contact Silver Plated Copper Alloy Touch Safety Main Connector Housing IEC 60950 Pass 1x4 Auxiliary Contacts IEC 60529 IP20 Pin Copper alloy, Au over Ni Socket BeCu, Au over Ni Socket Body Copper alloy, Sn bright over Ni Retention Clip Stainless Steel PPMX Contacts Gold Plated Copper Alloy Contact Termination Methods Crimp Hand Solder Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below a 30C temperature rise. Only SBO 60 has UL recognition. Limited by the thermal properties of the connector plastic housing. Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition. 4 Voltage capability of SBE housings is identical to SBO , but derated to meet EN1175-1 requirements. All Data Subject To Change Without Notice - 78 - www.andersonpower.com SECTION 3 SBE 80 / SBO 60