EBC Connectors E32 Female DIN 43589-1 Anderson Power Products family of Euro Features Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and Sturdy Advanced Polymer EN 1175-1. The connector design Housings incorporates an innovative, cost effective PBT-PC alloy housings provides superior contact carrier for ease of assembly. resistance to acids and temperature extremes The connectors have a Degree of DIN 43589-1 Voltage Keying Protection of IP23 per IEC 60529. The Dry-cell, wet-cell & universal keying plugs acid resistance and temperature range coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are Mating Compatibility with pure copper with silver plate for maximum Connectors of Other Manufacturers conductivity. Silver Plated Pure Copper APP E series connectors offer dimensional Contacts compatibility for air tube and auxiliary All materials meet RoHS requirements For lowest voltage drop and superior contacts over and above the DIN 43589-1 and are selected to ensure years of performance compatibility of housings and main contacts reliable service under adverse battery environments. SPECIFICATIONS Electrical Mechanical Current Rating (Amperes) * Life UL 340 a. No Load (mating cycles) >5000 EN1175-1:1998 300 b. Under Load (Hot Plug 5 mating cycles 96V) 800A CSA 260 Voltage Rating Average Mating / Unmating Force (lbf) 12 UL / CSA 600 (N) 53 EN1175-1:1998 150 Degree of Protection IP23 Wire Range Acid Resistence 1.38g / cm - Power Contacts - AWG (mm) 1/0 to 4/0 (50 / 95) Contact Retention - minimum (lbf) 100 - Auxiliary Contacts - AWG (mm) 12 to 10 (4 / 6) (N) 445 Dielectric Withstanding Voltage (AC) 2,200 Air Tube Rating 2 bar Average Contact Resistance (micro-ohms) 30 Operating Temperature (C) -25 to 75 Materials (F) -13 to 167 Housing PBT/PC blend Contacts Copper alloy, silver plate Hardware Steel, zinc chromate plate * Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum current carrying capacity is measured at 40C / 104F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling. ORDERING INFORMATION Connector Part Number Selection Accessories Main Coding Auxiliary Contacts Series Gender Contact Handle Key & Air Tubes Packaging Part E32 ** 5 50 - 1 0 2 9 Number Description E320-21 Twin air tube 5 Socket 9 Individual E16-89 Handle kit - low profile 00 None - Order Separately 0 None 8 Bulk E32-89 Handle kit - high profile 50 50 mm / 1/0 AWG 1 (2) Lower Auxiliary Contacts A320LP-MK Latch plate for mating side A320HL-MK Handle with latch & hardware 70 70 mm / 2/0 AWG 2 (2) Upper Auxiliary Contacts 994G4 Manual release bracket & handle 95 95 mm / 3/0 AWG 4 (2) Lower Auxiliary Contacts & 993G4 Manual release mounting plate 0 No 0 Grey, Wet Cell (2) Upper Auxiliary Contacts for mating half 1 Black 2 Green, Dry Cell 5 Air Tube ** A supplemental auxiliary holder will ship with each 3 Yellow, Universal 6 Air Tube & (2) Upper Auxiliary Contacts pair of contacts. 2016 Anderson Power Products, Inc. All rights reserved. APP , Anderson Power Products , the APP Logo are registered trademarks of Anderson Power Products, Inc. All Data Subject To Change Without NoticeMain Main Power Power Contact Contact E32 Female DIN 43589-1 ORDERING INFORMATION TEMPERATURE CHARTS Tooling E32 EBC Temperature Rise Part 50 45 Number Description 40 1387G3 Hydraulic tool for power contacts 35 E160-36 Extraction tool 30 Note: For tooling die information, see tooling chart on website. 25 20 DIMENSIONS 15 10 Socket Contact 5 0 0 50 100 150 200 250 300 350 400 Part - Wire - - A - - B - - C - Number mm AWG mm in. mm in. mm in. Current (A) 320-1150 50 1/0 14.5 0.57 11.0 0.43 64.5 2.54 50 mm 70 mm 95 mm 320-1170 70 2/0 17.0 0.67 13.0 0.51 64.5 2.54 Note: Temperature ratings based on Power Contacts energized only. 320-1195 95 3/0 19.8 0.78 15.0 0.59 70.5 2.78 C A E32 EBC Derating Curve (0.8 Derating per IEC 60512-3) 120 B 100 80 60 40 Upper Auxiliary Contact 20 E320-35 upper auxiliary contact for 4 mm ( 12 AWG) 0 0 50 100 150 200 250 300 2.05 0.16 52.1 4.1 Current (A) 0.11 50 mm 70 mm 95 mm 2.9 Note: Temperature ratings based on Power Contacts energized only. Lower Auxiliary Contact Housing Side View 160-13 lower auxiliary contact for 6 mm ( 10 AWG) 4.58 0.20 116.4 2.28 5.0 58.0 1.50 0.15 38.0 3.9 Handle / Lever Assembly / Latch Housing Front View Housing Top View 0.94 2.13 Handle & Lever Assembly Upper Auxiliary Contacts 24.0 54.0 Mounting Hardware Latch Plate 2.72 3.50 69.0 89.0 Lower Auxiliary Contacts 0.26 6.6(4) All Data Subject To Change Without Notice 2016-0070, DS-E32EBCF REV 9 HEADQUARTERS: Anderson Power Products , 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-0128 EUROPE: Anderson Power Products Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203 ASIA / PACIFIC: IDEAL Anderson Asia Pacific Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036 CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218 TAIWAN: IDEAL Anderson Asia Pacific Ltd., Taiwan Branch, 4F.-2, No.116, Dadun 20th St., Situn District, Taichung City 407, Taiwan (R.O.C.) T: +(886) 4 2310 6451 F:+(886) 4 2310 6460 www.andersonpower.com Temperature (C) Ambient Temperature (C)